2.6 Serial Interfaces and I/O Port

The RS232 and RS485 serial interfaces together with the I/O interface are physically con-
nected to the 10-pin panel socket. All three interfaces are not isolated from the router. The
pinout of this conector is described in the tables below.
Pin
1
2
3
We recommend connecting a termination resistor outside the router. Without termination re-
sistors, signal reflections off the unterminated end of the cable can cause data corruption.
Termination resistors also reduce electrical noise sensitivity due to the lower impedance.
Pin
4
5
Pin
6
7
8
9
10
The I/O user interface is designed for binary input processing and binary output control.
By default, the binary output is open, so it is not grounded. The maximum binary output load
is 36 V at 500 mA. The constant current supplied by the binary input is 3 mA.
Figure 16: Serial + I/O connector
Signal mark
Description
B (+)
IN/OUT
A (-)
IN/OUT
GND
GROUND
Table 7: Connection of RS485
Signal mark
Description
BIN
BINARY IN
BOUT
BINARY OUT
Table 8: Connection of I/O
Signal mark
Description
RXD
IN
CTS
IN
GND
GROUND
RTS
OUT
TXD
OUT
Table 9: Connection of RS232
17