Prepare the appliance
See your Installation Manual for help with these steps.
1. If the fireplace is already installed, remove the
access side doors, the front trim, the window, fuel
bed and liner panels. Be careful with the fuel bed
and liner panels as they are fragile.
2. Locate shut off valve and isolate. Disconnect the fuel
line from the valve after it is shut off.
3. Remove the cover panel surrounding the burner (4
screws).
4. Remove the rear baffle (6 screws)
5. Remove the burner by undoing 2 screws and pulling
the burner gently forward, then up.
2
6. Remove the burner module by undoing 12 screws
and lifting forward and then up. Be careful not to
hook the aeration block above, or the control
valve below, as you pull the burner module up.
Disconnect connections to the receiver to allow
the burner module to come free of the fireplace.
 WARNING
The connections and pipes on the
underside of the burner module are
very fragile. Damage to these pipes may
require replacement of the entire pilot
assembly. Be careful with these pipes as
you continue through these instructions.
Replace the burner injector
1. Using a 7/16" socket wrench with extension,
unscrew the old burner injector within the aeration
block.
Aeration block
Injector
2. Dispose of old burner injector.
3. Replace with new burner injector (see Specifications
table on page 1). Tighten in place with socket
wrench.
4. Unscrew and flip the air shutter stopper over.
Position required for each fuel is illustrated below.
Reattach using original screws.
Natural
gas
Propane