Millivolt Lighting Instructions - Empire Comfort Systems DVP20MS Installation Instructions And Owner's Manual

Direct-vent fireplace stove
Table of Contents

Advertisement

MILLIVOLT LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING
If you do not follow these instructions exactly, a fire or explosion may result causing property damage,
personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand.
When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area
for gas. Be sure to smell next to the floor because some
gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your building.
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
1.
STOP! Read the safety information on this page.
2.
Set the thermostat to lowest setting
3.
Turn OFF all electric power to the appliance (if applicable).
4.
Lower valve cover.
5.
Push in gas control knob slightly and turn clockwise
to "OFF" position.
NOTE: Knob cannot be turned from "PILOT" to "OFF" unless
knob is pushed slightly. Do not force.
6.
Wait ten minutes to clear out any gas. Then smell for gas,
including near the floor. If you smell gas, STOP! Follow
"B" in the safety information on this label. If you do not
smell gas, go to the next step.
7.
Find pilot - Follow metal tube from
gas control. The pilot is behind the
burner on the right side.
8.
Turn gas control knob counterclock-
wise
to "PILOT".
1.
Set the thermostat to lowest setting.
2.
Turn off all electric power to the appliance if service is
to be performed (if applicable).
3.
Lower valve cover.
42603-4-0421
LIGHTING INSTRUCTIONS
TO TURN OFF GAS TO APPLIANCE
WARNING
If you cannot reach your gas supplier, call the fire
department.
C. Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or
turn by hand, don't try to repair it; call a qualified service
technician. Force or attempted repair may result in a fire
or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.
9.
Push in gas control knob all the way and hold in. Repeat-
edly push the Piezo Ignitor Button until the pilot is lit.
Continue to hold the control knob in for about one minute
after the pilot is lit. Release knob, and it will pop back
up. Pilot should remain lit. If it goes out, repeat steps 5
through 9.
If knob does not pop up when released, stop immedi-
ately call a qualified service technician or gas supplier.
If the pilot will not stay lit after several tries, turn the gas
control knob to "OFF" and call your service technician
or gas supplier.
10. Turn gas control knob counterclockwise
11. Raise valve cover.
12. Turn ON all electric power to the appliance (if applicable).
13. Set the thermostat to desired setting.
4.
Push in gas control knob slightly and turn clockwise
to "OFF". Do not force.
5.
Raise valve cover.
to "ON".