CIB4-1 OPTIONAL BLOWER INSTALLATION INSTRUCTIONS - DVP20MS

Sharp edges, use protective gloves when installing.
Carton Contents:
Blower Assembly
Auto/On/Off Switch
Fan Control Bracket Assembly
Hardware Package:
(2) 10 x 1/2" Screw
(1) On/Off/Auto Switch
HARDWARE PACKAGE
#10 X 1/2 INCH SCREW
AUTO/ON/OFF SWITCH
Installing Optional CIB4 Blower
1.
Loosen, but do not remove, four hex-head screws located on
the exterior, bottom of the appliance.
2.
Position the blower assembly at the rear of the appliance.
The blower assembly has four keyholes for attachment to the
exterior, bottom of the appliance.
3.
Place the large diameter holes in the keyholes over and behind
the four hex-head screws that were loosened in Step 1. Push
inward on the blower assembly to lock the keyholes into position
behind the screws. Tighten four hex-head screws to secure
blower assembly to exterior, bottom of the appliance.
4.
Remove wire channel-left from appliance by removing two
10 x 1/2" screws on left side of the appliance.
5.
Route fan control wires through rectangular notch on wire
channel - left.
6.
Attach 1/4" push-on terminal from blue wire on the fan control
to the AUTO (top) tab on the switch.
7.
Attach 1/4" push-on terminal from black wire to the OFF (middle)
tab on the switch.
8.
Attach 1/4" push-on terminal from white wire on the fan control
to the ON (bottom) tab on the switch.
9.
Insert AUTO/OFF/ON switch into rectangular notch on wire
channel - left.
10. Bend the fan control tab, located on the left side of the back
of the unit, inward toward the unit. See Figure 39. Be sure tab
is bent at least 90 degrees to allow fan control bracket to slide
into slot.
11. Attach fan control with bracket onto rear cover with
two 10 x 1/2" screws provided in hardware package.
12. Route wires from fan control and ON/OFF/REMOTE switch
within wire channel.
13. Attach wire channel with two 10 x 1/2" screws from Step 4.
14. Installation of optional CIB4 blower is completed.
Page 58
CAUTION
Fan Control
The fan control is a non-adjustable automatic type The fan control
will require between 5 and 10 minutes of main burner operation
before the fan control "closes" and activates the blower. The blower
will continue to run between 5 and 10 minutes after the main burner
shuts off, before the fan control "opens" and deactivates the blower.
Cleaning
The blower wheel will collect lint and could require cleaning once
a year. If the air output decreases or the noise level increases, it
indicates a dirty wheel.
Blower Motor
The blower motor does not have oiling holes. Do not attempt to oil
blower motor.
BLOWER ASSEMBLY
BLOWER ASSEMBLY
FAN CONTROL
FAN CONTROL
AUTO/OFF/ON SWITCH
AUTO/OFF/ON SWITCH
RHEOSTAT
RHEOSTAT
KNOB
KNOB
NUT
NUT
WIRE CHANNEL - LEFT
WIRE CHANNEL - LEFT
Figure 39
42603-4-0421

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dvp30ms

Table of Contents