Millivolt Control Valve Lighting Instructions - Empire Comfort Systems VFP28IN3 L Series Installation Instructions And Owner's Manual

Unvented gas fireplace
Hide thumbs Also See for VFP28IN3 L Series:
Table of Contents

Advertisement

MILLIVOLT CONTROL VALVE LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING:
B. BEFORE LIGHTING
WHAT TO DO IF YOU SMELL GAS
1. STOP! Read the safety information label.
2. Open bottom louver assembly.
3. Set REMOTE/OFF/ON switch to
"OFF."
4. Turn off all electric power to the
5. Push in gas control knob slightly
and turn clockwise
"OFF." NOTE: Knob cannot be
turned from "PILOT" to "OFF" unless knob
is pushed in slightly. Do not force.
Then smell for gas, including
STOP! Follow "B" in the safety
information above. If you do not
smell gas, go to the next step.
7. Find pilot - Follow metal tube
from gas control. The pilot is
behind the burner on the right
1. Open bottom louver assembly.
2. Set REMOTE/OFF/ON switch to "OFF."
3. Turn off all electric power to the appliance if service is
26497-6-0511
LIGHTING INSTRUCTIONS
GAS CONTROL K N OB
SHOWN IN " O FF" POSITION.
to
REMOTE
OFF
ON
PILOT
THERMOPILE
ELECTRODE
THERMOCOUPLE
(LPG)
THERMOCOUPLE
(NATURAL)
TO TURN OFF GAS TO APPLIANCE
C. Use only your hand to push in or turn the gas control
side.
8. Turn gas control knob counterclockwise
"PILOT."
9. Push in control knob all the way and hold in. Repeat-
edly push the Piezo Ignitor Button until the pilot is lit.
minute after the pilot is lit. Release knob, and it will
pop back up. Pilot should remain lit. If it goes out,
repeat steps 5 through 9.
or gas supplier.
the gas control knob to "OFF" and call your ser-
vice technician or gas supplier.
10. Turn gas control knob counterclockwise
"ON."
11. Set REMOTE/OFF/ON switch to desired setting.
cable).
13. Close bottom louver assembly.
4. Push in gas control knob slightly and turn clockwise
to "OFF." Do not force.
5. Close bottom louver assembly.
to
to
-
Page 29

Advertisement

Table of Contents
loading

Table of Contents