Installation
Safety instructions for installation
Damage risk from incorrect installation.
Incorrect installation can cause damage to the hob.
The hob must only be installed by a qualified person.
Risk of electric shock.
Incorrect connection to the mains supply may result in an electric shock.
The hob must be connected to the electrical supply by a qualified person only.
Damage from falling objects.
Take care not to damage the hob when fitting wall units or a cooker hood above
it.
Fit the wall units and the cooker hood before the hob.
The veneer or laminate coatings of worktops (or adjacent kitchen
units) must be treated with 100 °C heat-resistant adhesive which will
not dissolve or distort. Any backmoulds must be of heat-resistant
material.
The hob must not be installed over a fridge, fridge-freezer, freezer,
dishwasher, washing machine, washer-dryer or tumble dryer.
This hob must not be installed above ovens or cookers unless
these have a built-in cooling down fan.
After installation, ensure that nothing can come into contact with
the connection cable and that it is without hindrance.
The electrical cable may not come into contact with any moving
kitchen component (e.g. a drawer) or be subject to mechanical
obstruction which could damage it.
Observe carefully the safety clearances listed on the following
pages.
11271190-06

Advertisement

loading

Summary of Contents for Miele KM 7564 FR

  • Page 1 *INSTALLATION* 11271190-06 Installation Safety instructions for installation  Damage risk from incorrect installation. Incorrect installation can cause damage to the hob. The hob must only be installed by a qualified person.  Risk of electric shock. Incorrect connection to the mains supply may result in an electric shock. The hob must be connected to the electrical supply by a qualified person only.
  • Page 2 *INSTALLATION* 11271190-06 Installation Safety distances Safety distance above the hob The safety distance specified by the manufacturer of the cooker hood must be maintained between the hob and the cooker hood above it. If combustible objects are installed above the hob (e.g., cabinets, utensil rail, etc.), a minimum safety distance of 600 mm must be maintained.
  • Page 3 *INSTALLATION* 11271190-06 Installation Safety distances to the sides and back of the appliance It is advisable to install the hob with plenty of space either side of it. The minimum distance  shown below must be maintained between the back of the hob and a tall unit or wall.
  • Page 4 *INSTALLATION* 11271190-06 Installation Minimum safety distance underneath Intermediate shelf the hob It is not necessary to fit an intermediate To ensure sufficient ventilation to the shelf underneath the hob, but one may hob, a minimum safety distance must be fitted if you wish. be left between the underside of the Leave a gap of 10 mm at the back hob and any oven, intermediate shelf or...
  • Page 5 *INSTALLATION* 11271190-06 Installation Safety distance when installing the appliance near a wall with additional niche cladding A minimum safety distance must be maintained between the worktop cut-out and any niche cladding to protect it from heat damage. If the niche cladding is made from a combustible material (e.g. wood) a minimum safety distance ...
  • Page 6: Installation Notes

    *INSTALLATION* 11271190-06 Installation Tiled worktops Installation notes Surface-mounted installation Seal between the hob and the worktop Grout lines  and the hatched area underneath the hob frame must be smooth and even. If they are not the hob will not sit flush with the worktop and the sealing strip underneath the hob will not provide a good seal ...
  • Page 7 *INSTALLATION* 11271190-06 Installation Flush-fit installation Natural stone worktops The hob is set directly in the cut-out. Flush-fit installation is only possible in natural stone (granite, marble), solid Solid wood worktops, tiled worktops, wood and tiled worktops. Certain glass worktops models are suitable for building into The hob is secured inside the cut-out glass worktops –...
  • Page 8: Installation Dimensions - Surface-Mounted

    *INSTALLATION* 11271190-06 Installation Installation dimensions – Surface-mounted All dimensions are given in mm. KM 7564 FR a Front b Mains connection box The mains connection cable (L = 1440 mm) is supplied loose...
  • Page 9 *INSTALLATION* 11271190-06 Installation KM 7564 FL a Front b Mains connection box The mains connection cable (L = 1440 mm) is supplied loose...
  • Page 10 *INSTALLATION* 11271190-06 Installation KM 7574 FR a Front b Mains connection box The mains connection cable (L = 1440 mm) is supplied loose...
  • Page 11 *INSTALLATION* 11271190-06 Installation KM 7574 FL a Front b Mains connection box The mains connection cable (L = 1440 mm) is supplied loose...
  • Page 12 *INSTALLATION* 11271190-06 Installation KM 7575 FR a Front b Mains connection box The mains connection cable (L = 1440 mm) is supplied loose...
  • Page 13 *INSTALLATION* 11271190-06 Installation KM 7575 FL a Front b Mains connection box The mains connection cable (L = 1440 mm) is supplied loose...
  • Page 14 *INSTALLATION* 11271190-06 Installation KM 7594 FR a Front b Mains connection box The mains connection cable (L = 1440 mm) is supplied loose...
  • Page 15 *INSTALLATION* 11271190-06 Installation KM 7594 FL a Front b Mains connection box The mains connection cable (L = 1440 mm) is supplied loose...
  • Page 16 *INSTALLATION* 11271190-06 Installation KM 7684 FL a Front b Mains connection box The mains connection cable (L = 1440 mm) is supplied loose...
  • Page 17: Surface-Mounted Installation

    *INSTALLATION* 11271190-06 Installation Surface-mounted installation If the seal does not sit flush with the worktop in the corners, the corner  Create the worktop cut-out. radius (≤ R4) can be carefully cut to fit Remember to maintain the minimum using a jigsaw. safety distances (see “Installation –...
  • Page 18 *INSTALLATION* 11271190-06 Installation Installation dimensions – Flush-fit All dimensions are given in mm. KM 7564 FL a Front b Mains connection box The mains connection cable (L = 1440 mm) is supplied loose c Stepped cut-out, natural stone worktop d Wooden batten 12 mm (not supplied)
  • Page 19 *INSTALLATION* 11271190-06 Installation KM 7574 FL a Front b Mains connection box The mains connection cable (L = 1440 mm) is supplied loose c Stepped cut-out, natural stone worktop d Wooden batten 12 mm (not supplied)
  • Page 20 *INSTALLATION* 11271190-06 Installation KM 7575 FL a Front b Mains connection box The mains connection cable (L = 1440 mm) is supplied loose c Stepped cut-out, natural stone worktop d Wooden batten 12 mm (not supplied)
  • Page 21 *INSTALLATION* 11271190-06 Installation KM 7594 FL a Front b Mains connection box The mains connection cable (L = 1440 mm) is supplied loose c Stepped cut-out, natural stone worktop d Wooden batten 12 mm (not supplied)
  • Page 22 *INSTALLATION* 11271190-06 Installation KM 7684 FL a Front b Mains connection box The mains connection cable (L = 1440 mm) is supplied loose c Stepped cut-out, natural stone worktop d Wooden batten 12 mm (not supplied)
  • Page 23: Flush-Fit Installation

    *INSTALLATION* 11271190-06 Installation Flush-fit installation  Damage from unsuitable sealant.  Create the worktop cut-out. Unsuitable sealant can damage natural stone. Remember to maintain the minimum safety distances (see “Installation – For natural stone worktops and Safety distances”). natural stone tiles, only use silicone sealant that is specially formulated ...
  • Page 24: Electrical Connection

    The connection data is quoted on the maintenance and repairs can cause data plate. Please ensure these match considerable danger for the user. the household mains supply. Miele cannot be held liable for Please see wiring diagrams for damage or injury caused by connection. unauthorised installation,...
  • Page 25 A suitable Switch the lever from 1 (on) to 0 (off). connection cable is available from your Residual current device (RCD) Miele dealer.  Switch the main switch from 1 (on) to 0 (off) or press the test button.
  • Page 26 *INSTALLATION* 11271190-06 Installation Wiring diagram a b c d e 200-240 V~ 200-240 V~ 200-240 V~ (L3) 200-240 V~ 200-240 V~ b c d (L2) 200-240 V~...