o The mains terminal block is located on the underside of the
cooktop and the terminals are accessible by removing the
terminal block cover. This is done by depressing the front of the
cover and releasing it from the securing clips.
o The cable connections must be in accordance with the diagram
located on the bottom of the cooktop (see above). The links must
also be positioned as indicated.
o You should use a good quality screwdriver to carefully, fully tighten
ALL of the terminal screws.
o If when the cooktop is first switched on, only two of the
zones work, you should recheck that the terminal screws are
all fully tightened and the links are in position. This should
be done before contacting the Customer Care Department.
o IMPORTANT: The appliance must NOT be connected to the mains
supply by means of a 10A or 15A plug and socket.
o The cable can be looped if necessary, but make sure that is not
kinked or trapped when the cooktop is in position. Care must be
taken to avoid the cable being in contact with hot parts of the
appliance.