3.5

Connection of extension blocks to main unit

1) Remove the connector cover from the right
side of the main unit.
2) Slide up the slide lock of the main unit, and
then connect an extension block.
3) Slide down the slide lock to lock the exten-
sion block.
Connect the other extension blocks in the
same way.
3.6

DIN rail mounting

The DIN 46277 rail (35 mm, 1.4 inches) can be directly
installed on the FX
(Do not use any screws for this installation.) To remove
the main body, slightly slide down the DIN rail mounting
clip. Slide the clip farther, and the rail will be locked with
the clip left open.
To connect the FX
DIN rail mounting clip in the direction of the arrow as
shown to the right.
series programmable controller.
2NC
series extension blocks, slide the
2N
Figure 3.3 :
Slide lock
Slide lock
Main unit
Figure 3.6 :
Remove
When DIN rail is
installed
Installation notes 3.
Extension block
Locks the clip.
When directly installed
(before shipment)