HP 8920A Application Handbook page 296

Rf communications test set
Hide thumbs Also See for 8920A:
Table of Contents

Advertisement

RF Analyzer Specifications
TDMA Analyzer
296
HP 8920B Option 500 (includes HP 83201B)
Frequency Range: 824 MHz to 894 MHz
Input Level Range:
RF In/Out: 1mW to 60W (0 to 47.8 dBm)
Antenna In: −36 to +17 dBm
Input Frequency Setting Error: 1kHz
RX DSP Level Setting Range: −23 to 0dB full scale
Residual Error Vector Magnitude: %<1.3%
Error Vector Magnitude Measurement Accuracy: ±4% plus 2% of read-
ing
Residual Phase Error: %<1.0°
Residual Magnitude Error: %<0.9%
I/Q Origin Offset Accuracy: ±0.5 dB for values to −40 dBc
Frequency Error Accuracy: ±2.5 Hz plus reference accuracy