AM Receivers
148
On the Test Set using the knob and data entry keys:
15. Slowly increase the Amplitude until squelch just remains open.
Critical Squelch is displayed as Amplitude as shown.
•
Record this level.
Squelch
Sensitivity
16. Decrease Amplitude until the Receiver's squelch just closes.
•
Record this level.
Calculate the measurement:
17. Critical Squelch Hysteresis is the difference between the two readings.
On the Radio set the Receiver's Controls as follows:
18. Set the Receiver's squelch control to maximum.
On the Test Set using the knob and data entry keys:
19. Increase Amplitude until the Receiver's squelch just opens.
•
Record this level.
20. Record the maximum squelch sensitivity is displayed as Amplitude as
shown.
21. Decrease Amplitude until the Receiver's squelch just closes.
•
Record this level.
Calculate the reading:
22. Maximum Squelch Hysteresis is the difference between the two readings.
RX TEST
SINAD
dB
0
20.44
24
RF Gen Freq
AFGen1 Freq
AFGen2 Freq
28.310000
1.0000
1.0000
MHz
kHz
AFGen1 To
AFGen2 To
Amplitude
1.58
AM
FM
uV
30.0
Off
%
Atten Hold
On/Off
Output Port
RF Out/Dupl
AC Level
V
0.7878
To Screen
Filter 1
RF GEN
50Hz HPF
kHz
RF ANL
AF ANL
Filter 2
SCOPE
15kHz HPF
SPEC ANL
ENCODER
DECODER
Ext Load R
RADIO INT
8.00
Ω
More