HP 8920A Application Handbook page 106

Rf communications test set
Hide thumbs Also See for 8920A:
Table of Contents

Advertisement

FM Receivers
Additional Equipment
Required
Special Test Considerations
106
Test Load
See
"Receiver Test Loads" on page
See
"Coded Squelch" on page
Measurement Procedure:
1 Connect the Receiver as shown.
On the Test Set:
2 Press the PRESET key.
3 Press the RX key.
Using the knob and data entry keys:
4 Set RF Gen Freq to the receiver operating frequency.
5 Set Amplitude to −47 dBm (1 mV).
6 Set AFGen1 To 60% of the Receiver's specified maximum frequency de-
viation (typically 3 kHz).
7 Set Filter 1 to <20 Hz HPF.
8 Set Ext Load R to the test load resistance.
9 Set AC Level meter to measure Watts.
On the Radio set the Receiver's Controls as follows:
10 Set power to ON.
11 If required, set frequency to the same value as
12 Set RF Gain to maximum (if equipped).
13 Set coded squelch feature to minimum (if equipped).
14 Set the volume control until the AC Level reads 50% of the Receiver's
specified audio output.
Refer to the audio output specifications for the receiver being tested.