Page 1
Preface Introduction Installing the Device RUGGEDCOM RX1000P Communication Ports Technical Specifications Dimension Drawings Installation Guide Certification 4/2015 RC1050-EN-03...
Page 2
Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
Installation Guide Preface Preface This guide describes the RUGGEDCOM RX1000P. It describes the major features of the device, installation, commissioning and important technical specifications. It is intended for use by network technical support personnel who are responsible for the installation, commissioning and maintenance of the device.
Siemens sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: • Online Visit http://www.siemens.com/automation/support-request...
RUGGEDCOM RX1000P Chapter 1 Installation Guide Introduction Introduction The RX1000P is an industrially hardened, Power over Ethernet (PoE) enabled, cyber security appliance with integrated router, firewall and VPN functionality. The device may be equipped with up to four 10/100Base-TX 802.3af (PoE) copmliant Ethernet ports.
Page 8
Chapter 1 RUGGEDCOM RX1000P Introduction Installation Guide Security Appliance Functions • Integrated Router/Firewall/VPN • Stateful Firewall with NAT • Full IPSec Virtual Private Networking • VPN with 3DES, DES and AES support • RADIUS centralized password management Rated for Reliability in Harsh Environments •...
RUGGEDCOM RX1000P Chapter 1 Installation Guide Introduction ▪ PPPoE over DSL ▪ GOOSE messaging support • IP ▪ Routing: VRRP, OSPF, RIP, BGP ▪ DHCP Agent (Option 82 capable) ▪ Traffic prioritization, NTP Server, IP Multicast Routing Section 1.2 Ports, Controls and Indicator LEDs The RX1000P features various ports, controls and indicator LEDs on the front panel for configuring and troubleshooting the device.
This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd. could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
Chapter 2 RUGGEDCOM RX1000P Installing the Device Installation Guide NOTE For detailed dimensions of the device with either rack, DIN rail or panel hardware installed, refer to Chapter 5, Dimension Drawings. The following sections describe the various methods of mounting the device: •...
RUGGEDCOM RX1000P Chapter 2 Installation Guide Installing the Device Section 2.1.2 Mounting the Device on a DIN Rail For DIN rail installations, the RX1000P can be equipped with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be slid onto a standard 35 mm (1.4 in) DIN rail.
Chapter 2 RUGGEDCOM RX1000P Installing the Device Installation Guide Figure 4: Panel Mounting 1. Screw 2. Panel/DIN Rail Adaptor Install the supplied screws to secure the adapters to the panel. Section 2.2 Connecting Power The RX1000P supports a single AC or DC power supply, and a separate 48 VDC power supply for PoE ports.
RUGGEDCOM RX1000P Chapter 2 Installation Guide Installing the Device • Section 2.2.1, “Connecting AC Power” • Section 2.2.2, “Connecting DC Power” • Section 2.2.3, “Wiring Examples” Section 2.2.1 Connecting AC Power To connect a high AC power supply to the device, do the following: CAUTION! Electrical hazard –...
Chapter 2 RUGGEDCOM RX1000P Installing the Device Installation Guide Connect the negative wire from the power source to the negative/neutral (-/N) terminal on the terminal block. For more information, refer to Section 2.2.3, “Wiring Examples”. Install the supplied metal jumper between terminals 2, 4 and 6 to connect the surge ground terminals to the chassis ground terminal.
RUGGEDCOM RX1000P Chapter 2 Installation Guide Installing the Device Figure 6: Terminal Block Wiring 1. Screw-Type Terminal Block 2. Pluggable Terminal Block 3. Jumper 4. Positive/Live (+/L) Terminal 5. Negative/Neutral (-/N) Terminal 6. Surge Ground Terminal 7. Chassis Ground Terminal Connect the negative wire from the power source to the negative/neutral (-/N) on the terminal block.
Page 18
Chapter 2 RUGGEDCOM RX1000P Installing the Device Installation Guide Figure 7: Single AC Power Supply Figure 8: Single DC Power Supply Wiring Examples...
Page 19
RUGGEDCOM RX1000P Chapter 2 Installation Guide Installing the Device Figure 9: Dual AC/DC Power Supply Figure 10: Dual DC Power Supply Wiring Examples...
Chapter 2 RUGGEDCOM RX1000P Installing the Device Installation Guide Figure 11: Dual AC/DC or AC and 48 V PoE Power Supply Section 2.3 Connecting the Failsafe Alarm Relay The failsafe relay can be configured to latch based on alarm conditions. The NO (Normally Open) contact is closed when the unit is powered and there are no active alarms.
Section 2.5 Cabling Recommendations Siemens does not recommend the use of copper cabling of any length for critical, real-time substation automation applications. All copper Ethernet ports on RUGGEDCOM products include transient suppression circuitry to protect against damage from electrical transients and conform with IEC 61850-3 and IEEE 1613 Class 1 standards.
Installing the Device Installation Guide Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
RUGGEDCOM RX1000P Chapter 3 Installation Guide Communication Ports Communication Ports The RX1000P can be equipped with various types of communication ports to enhance its abilities and performance. To determine which ports are equipped on the device, refer to the factory data file available through ROX .
RUGGEDCOM RX1000P Chapter 3 Installation Guide Communication Ports Section 3.2 WAN Ports The RX1000P can optionally be equipped with T1/E1 WAN ports, which communicate on standard telephony communication lines. T1/E1 WAN ports are equipped with standard RJ45 receptacles. The following is the pin-out for the T1/E1 ports:...
Chapter 3 RUGGEDCOM RX1000P Communication Ports Installation Guide Section 3.4 DDS Ports The RX1000P can optionally be equipped with a 56/64 kbps DDS (Data Distribution Service) card that uses standard RJ45 receptacles. The following is the pin-out for the DDS ports:...
RUGGEDCOM RX1000P Chapter 3 Installation Guide Communication Ports NOTE This product meets the applicable Industry Canada technical specifications. The Ringer Equivalence Number is an indication of the maximum number of devices allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the RENs of all the devices does not exceed five.
RUGGEDCOM RX1000P Chapter 3 Installation Guide Communication Ports Figure 23: PTP Card 1. IEEE 1588 Ethernet Interface 2. GPS Antenna Input 3. IRIG-B AM Output 4. IRIG-B PWM (TTL) or PPS Output 1 5. IRIG-B PWM (TTL) or PPS Output 2 NTP is the standard for synchronizing the clocks of computer systems throughout the Internet and is suitable for systems that require accuracies in the order of 1 ms.
Chapter 3 RUGGEDCOM RX1000P Communication Ports Installation Guide Figure 24: IRIG-B Simplified Schematic 1. Source 2. Cabling 3. Device The maximum number of devices (N) that can be connected to the source is determined by checking if the source current (IS) required to drive the connected devices is less than the maximum drive current the source can provide, and verifying that the load voltage (VL) the connected devices see is greater than the minimum required voltage.
The time delay is dependent on the type of dielectric material in the cable and ranges from 1 to 2 ns/ft. Siemens provides a method to account for this delay through the web management interface by entering the time delay into the cable compensation box under PTP General Configuration.
Siemens also recommends installing lightning arrestors in the antenna line to protect the receiver and connected devices. If a lightning arrestor is installed it is important to ensure that it has a low impedance path to ground.
RUGGEDCOM RX1000P Chapter 3 Installation Guide Communication Ports Name Description Carrier Detect Receive data Transmit Data Data Terminal Ready Common Ground Data Set Ready Request To Send Figure 25: Serial DB9 Port Pin Configuration Clear To Send RI (No Ring Indicator...
Chapter 3 RUGGEDCOM RX1000P Communication Ports Installation Guide Figure 26: EVDO Cellular Modem The EVDO cellular modem has the following minimum requirements: Frequency Range (MHz) Maximum RX Diversity Band VSWR Allowable Support Gain (dBi) Cell 824-849 869-894 <2:1 <2:1 4.95...
RUGGEDCOM RX1000P Chapter 3 Installation Guide Communication Ports Supported Frequency Bands WARNING! Electromagnet radiation hazard – risk of serious injury. Do not exceed the maximum antenna gain. Aside from causing cellular interference for other devices that use the same band, adverse health effects for individuals in the area may occur.
Chapter 3 RUGGEDCOM RX1000P Communication Ports Installation Guide Insert the SIM card with the angled side first. An audible click will indicate the SIM card is in position. Install the access panel. Connect power to the device. Supported Frequency Bands WARNING! Electromagnet radiation hazard –...
Page 37
RUGGEDCOM RX1000P Chapter 3 Installation Guide Communication Ports 120Ω 10nF 120Ω 10nF Figure 29: Recommended RS485 Wiring 1. RX1000P Device 2. Common (Isolated Ground) 3. Negative 4. Positive 5. Shield to Earth (Connected At a Single Point) 6. RS485 Devices (32 Total)
RUGGEDCOM RX1000P Chapter 4 Installation Guide Technical Specifications Technical Specifications The following sections provide important technical specifications related to the device and available modules: • Section 4.1, “Power Supply Specifications” • Section 4.2, “PoE Power Supply Specifications” • Section 4.3, “Failsafe Relay Specifications”...
RUGGEDCOM RX1000P Chapter 6 Installation Guide Certification Certification The RX1000P device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. • Section 6.1, “Agency Approvals” • Section 6.2, “FCC Compliance”...
Chapter 6 RUGGEDCOM RX1000P Certification Installation Guide Section 6.4 EMI and Environmental Type Tests The RX1000P has passed the following EMI and environmental tests. IEC 61850-3 EMI Type Tests NOTE • In the case of an all fiber port configuration, this product meets all Class 2 requirements. Otherwise, all Class 1 requirements are met for copper ports.
Page 49
RUGGEDCOM RX1000P Chapter 6 Installation Guide Certification Test Description Test Levels Severity Levels IEC 61000-4-12 Damped Oscillatory Signal ports 2.5 kV common, 1 kV differential mode @ 1 MHz DC Power ports 2.5kV common,1kV differential mode @ 1 MHz AC Power ports 2.5 kV common,...
Chapter 6 RUGGEDCOM RX1000P Certification Installation Guide Test Description Test Levels AC Power ports 2.5 kV common and differential mode @ 1 MHz IEEE C37.90 HV Impulse Signal ports 5 kV (Failsafe Relay) DC Power ports 5 kV AC Power ports 5 kV IEEE C37.90...