Siemens RUGGEDCOM RM1224 Operating Instructions Manual

Industrial remote communication remote networks

Advertisement

Quick Links

RUGGEDCOM
Industrial Remote Communication
Remote Networks
RUGGEDCOM RM1224
Operating Instructions
10/2016
RC1260-EN-02
Preface
Description of the device
Installation
Connecting up
Dimension drawing
Technical specifications
Approvals
1
2
3
4
5
A

Advertisement

Table of Contents
loading

Summary of Contents for Siemens RUGGEDCOM RM1224

  • Page 1 Preface Description of the device Installation RUGGEDCOM Connecting up Industrial Remote Communication Remote Networks Dimension drawing RUGGEDCOM RM1224 Technical specifications Operating Instructions Approvals 10/2016 RC1260-EN-02...
  • Page 2: Rc1260-En

    Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept.
  • Page 4 You will find the SIMATIC NET glossary here: ● SIMATIC NET Manual Collection or product DVD The DVD ships with certain SIMATIC NET products. ● On the Internet under the following entry ID: 50305045 (http://support.automation.siemens.com/WW/view/en/50305045) RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 5: Table Of Contents

    Power supply ..........................28 Grounding ..........................29 Digital input/output ........................30 Antennas ..........................32 Ethernet port ...........................35 Inserting and removing the PLUG ..................36 Dimension drawing ..........................39 RUGGEDCOM RM1224 ......................39 Technical specifications ........................41 Approvals.............................. 45 EU declaration of conformity....................47 A.1.1 R&TTE ............................47 A.1.1.1 Protection of health and safety ....................47...
  • Page 6 Table of contents A.1.3 Products ..........................50 RCM / C-TICK ........................50 IECEx ............................. 51 FM certification........................51 UL certification (product safety) ..................... 51 EAC ............................52 Index 53 RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 7: Description Of The Device

    You will find more detailed information in "Accessories (Page 8)".  SIM card Use the SIM card from the chosen mobile wireless provider Article numbers Type Article number Description RUGGEDCOM 6GK6 108-4AM00-2BA2 Mobile wireless router for 4G (LTE) with antenna RM1224 diversity RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 8: Accessories

    ANT794-4MR Omnidirectional antenna for GSM (2G), UMTS 6NH9860-1AA00 (3G) and LTE(4G); weatherproof for indoor and outdoor areas; 5 m connecting cable connected permanently to the antenna; SMA connector, including installation bracket, screws, wall plugs RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 9: Led Display

    Description of the device 1.3 LED display LED display RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 10 No VPN connection is established. All configured VPN connections are established. Flashing Only some of the configured VPN connections are established. Ethernet connection to local computer or LAN not established Ethernet connection to local computer or LAN established RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 11 Description of the device 1.4 SET button Status Meaning Device receiving / sending data Digital input inactive Digital input active. Digital output inactive Digital output active. RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 12: Set Button

    Description of the device 1.4 SET button SET button With a M-800RUGGEDCOM RM1224, the SET button is on the front of the housing beside the LED display. RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 13 – Now release the button. The bootloader waits in this state for a new firmware file that you can download using TFTP. You will find more information in the section "Service and Maintenance" in the RUGGEDCOM RM1224 Web Based Management configuration manual. ● Reset to factory defaults –...
  • Page 14: C-Plug And Key-Plug

    PLUG inserted, the device starts up with the configuration data on the PLUG. License information on the KEY-PLUG In addition to the configuration, the KEY-PLUG also contains a license that allows the use of Siemens Remote Services. RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 15 KEY-PLUG SINEMA 6GK5908-0PB00 Exchangeable storage medium (256 MB) to enable the connection functionality to SINEMA Remote Connect and for accepting configuration data. See also Inserting and removing the PLUG (Page 36) RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 17: Installation

    General notes on use according to ATEX and IECEx WARNING To comply with EC Directive 94/9 (ATEX95) or the conditions of IECEx, this enclosure or cabinet must meet the requirements of at least IP54 in compliance with EN 60529. RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 18: Securing The Housing

    The wall mounting must be capable of supporting four times the weight of the device, but at least 50 N. For information on the weight, refer to the section "Technical specifications (Page 41)". Requirement There is a SIM card for the device. RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 19: Installation On The Din Rail

    8. Connect the terminal with as short a cable as possible ≤ 150 mm and a large cross- sectional area ≥ 2.5 mm² to the ground of the system, see section "Grounding (Page 29)" Installation on the DIN rail Requirement There is a SIM card for the device. RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 20 ≥ 2.5 mm² to the ground of the system, see section "Grounding (Page 29)" Dismantling 1. Disconnect all connected cables. 2. Using a screwdriver, pull down the catch on the rear of the device. 3. Pull lower part of the device away from the DIN rail. RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 21: Installing On The S7-300 Standard Rail

    8. Connect the terminal with as short a cable as possible ≤ 150 mm and a large cross- sectional area ≥ 2.5 mm² to the ground of the system, see section "Grounding (Page 29)" RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 22: Installing On The S7-1500 Standard Rail

    5. Connect the power supply, refer to the section "Power supply (Page 28)". 6. Fit the connectors for the digital input and digital output, refer to the section "Digital input/output (Page 30)". RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 23 ≥ 2.5 mm² to the ground of the system, see section "Grounding (Page 29)" Dismantling 1. Disconnect all connected cables. 2. Using a screwdriver, pull down the catch on the rear of the device. 3. Remove the device from the standard rail. RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 25: Connecting Up

    NEC Class 2, as described by the National Electrical Code (r) (ANSI / NFPA 70). If the equipment is connected to a redundant power supply (two separate power supplies), both must meet these requirements. RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 26 WARNING Take measures to prevent transient voltage surges of more than 40% of the rated voltage. This is the case if you only operate devices with SELV (safety extra-low voltage). RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 27: Sim Card

    2. Place the SIM card in the tray so that the card audibly locks in place and so that its gold- plated contacts remain visible. 3. Then push the tray with the SIM card completely back into the housing. RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 28: Power Supply

    Power supply The power supply is connected using a 5-pin terminal block. The power supply is non- floating. Signal Description 24 VDC Ground Ground 24 VDC Functional ground, refer to the section Grounding (Page 29)" RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 29: Grounding

    DIN rail terminal, but goes directly to the mounting plate or DIN rail terminal. The RUGGEDCOM RM1224 has a terminal for grounding, refer to the section "Power supply (Page 28)".
  • Page 30: Digital Input/Output

    Damage due to voltage being too high or too low The voltage at the digital input/output must not exceed 30 VDC and not fall below -30 VDC, otherwise the digital input/output will be destroyed. RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 31 If there is an adequate switching voltage at the digital input, the digital input is active and the "DI" LED is lit. This means that, for example a local application connected to the in port can trigger an alarm message by SMS outside the IP data connection. RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 32: Antennas

    Use the antennas from the accessories program for the RM1224 device. You will find more detailed information in "Accessories(Page 8)". If you use a different antenna, there is no guarantee the device will function according to the specification. RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 33 WARNING Danger due to lightning strikes Installing this lightning protector between an antenna and a RUGGEDCOM RM1224 is not adequate protection against a lightning strike. Most lightening protectors only works within the framework of a comprehensive lightning protection concept. If you have questions, ask a qualified specialist company.
  • Page 34 If the "Q" LED is lit permanently, the signal quality is good. For more detailed information, refer to the section "LED display (Page Error! Bookmark not defined.)". Avoid large metal objects in the immediate vicinity. RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 35: Ethernet Port

    To set up the device, connect a PC with a Web browser to one of the Ethernet ports. For the connection, use a path cable with an RJ-45 plug. You will find the properties of the Ethernet interface in the technical specifications. RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 36: Inserting And Removing The Plug

    PLUG was removed, there is a restart. If a valid KEY-PLUG was inserted in the device, the device changes to a defined error state following the restart. With RUGGEDCOM RM1224, the wireless interface is deactivated in this case. Inserting the PLUG 1.
  • Page 37 3.8 Inserting and removing the PLUG Removing the PLUG 1. Turn off the power to the device. 2. Insert a screwdriver between the front edge of the PLUG and the slot and release the PLUG. 3. Remove the PLUG. RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 39: Dimension Drawing

    Dimension drawing RUGGEDCOM RM1224 Dimensions are specified in mm. Image 4-1 RM1224 side view RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 40 Dimension drawing 4.1 RUGGEDCOM RM1224 Image 4-2 RM1224 front view RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 41: Technical Specifications

    Coding scheme uplink: CS 1 ... 4, MCS 1 ... 9  Transmission speed  Downlink: up to 237 kbps: Uplink: up to 237 kbps:  GPRS Properties Multislot class 12, end device class B, coding scheme 1 … 4 RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 42 ≤ 95% at 25 °C, no condensation Design, dimensions and weight Module format Compact module S7-1500 UL certified operational temperature range -20 °C to +70 °C IEC environmentally type tested (16 hours) from -40 °C to +75 °C RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 43 Remote access with HTTPS  SNMP and SNMP traps  Type tests IEC 60068-2-1 Cold Temperature -40 ℃ for 16 hours (Test Ad) IEC 60068-2-2 Dry Heat (Test Bd) +75 ℃ for 16 hours RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 45: Approvals

    The installation of expansions that are not approved for RUGGEDCOM products or their target systems may violate the requirements and regulations for safety and electromagnetic compatibility. Only use expansions that are approved for the system. RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 46 RUGGEDCOM products are regularly submitted to the relevant authorities and approval centers for approvals relating to specific markets and applications. You will also find the current approvals for the product on the Internet pages of Siemens Automation Customer Support under the following entry ID: 80046561 (http://support.automation.siemens.com/WW/view/en/80046561/134200)
  • Page 47: Eu Declaration Of Conformity

    DE-76181 Karlsruhe Germany You will find the EC declaration of conformity for these products on the Internet pages of Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/15914/cert). The RUGGEDCOM products described in these Operating Instructions meet the requirements of the following EC directives: ●...
  • Page 48: Emc

    EN 61000-6-3+A1+AC Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments EN 61000-6-4+A1 Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 49: Efficient Use Of The Radio Spectrum

    EC directive 2011/65/EC for the restriction of the use of certain hazardous substances in electrical and electronic equipment: Applied standard: EN 50581 Technical documentation for the assessment electrical and electronic products with respect to restriction of hazardous substances RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 50: Products

    LTE FDD 20 8.76 RCM / C-TICK The products meet the requirements of the AS/NZS CISPR11 : 2011 standard (Industrial, scientific and medical equipment - Radio- frequency disturbance characteristics - Limits and methods of measurement). RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 51: Iecex

    FM Hazardous (Classified) Location Electrical Equipment: Non Incendive / Class I / Division 2 / Groups A,B,C,D / T4 and Non Incendive / Class I / Zone 2 / Group IIC / T4 UL certification (product safety) RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 52: Eac

    IEC environmentally type tested (16 hours) from -40 °C to +75 °C. Marking for the customs union EAC (Eurasian Conformity) Customs union of Russia, Belarus and Kazakhstan Declaration of the conformity according to the technical regulations of the customs union (TR CU) RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 53: Index

    System manual, 46 Ethernet interface, 35 External power supply Wall mounting, 19 China, 29 Glossary, 4 Grounding, 29 Installation DIN rail, 20 S7-1500 standard rail, 22, 22 S7-300 standard rail, 21 Wall, 19 KEY-PLUG, 14 RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...
  • Page 54 Index RUGGEDCOM RM1224 Operating Instructions, 10/2016, RC1260-EN-02...