16
Click Disk Management.
17
Select the step depending on your reason for a created volume.
To create a new volume (except for a RAID 5 or mirrored volume):
(1) Right-click the new dynamic disk and select New Volume.
(2) Follow the instructions on the screen to create a new volume.
To restore a RAID 5 volume (RAID resynchronization):
(1) Right-click the volume labeled "Failed Redundancy" and click Restore Volume.
(2) When "Select one of the disks listed below." is displayed, select the drive to restore and click OK.
Perform steps (1) and (2) for each volume that requires RAID resynchronization.
(3) Right-click the volume labeled "Missing" and select Remove Disk.
To restore a mirrored volume (RAID resynchronization):
(1) Right-click the volume labeled "Failed Redundancy" and click Remove Mirror.
(2) When "Remove Mirror" is displayed, select the drive with its status missing and click Remove Mirror.
(3) When "Are you sure you want to remove the mirror?" is displayed, click OK.
Perform steps (1) to (3) for each volume that requires RAID resynchronization.
(4) Select the new volume where mirroring will be performed and select Add Mirror.
(5) When "Add Mirror" is displayed, select the drive where mirroring will be performed with the selected
volume and click Add Mirror.
If a Mirrored Volume Failed to Restore
If a mirrored volume doesn't restore the first time, try the steps above a second time. If the mirrored volume still
cannot be restored, contact Buffalo technical support for assistance.
A Drive Failure Occurs among Drives 3–6
1
Double-click the
icon to start NAS Navigator2.