Resetting Oap Modules; Procedure To Reset An Oap Module - H3C MSR 810 Configuration Manual

Comware 7 oaa
Hide thumbs Also See for MSR 810:
Table of Contents

Advertisement

Procedure
To log in to an OAP module from the CLI of the device, execute one of the following commands in
user view:
In standalone mode:
oap connect system system-name
In IRF mode:
oap connect slot slot-number [ system system-name ]

Resetting OAP modules

About this task
You can reset an OAP module to restore it to normal operation in the following situations:
The OAP module fails.
The OAP module is not operating correctly. For example, the OAP module does not respond to
your operation.
Pressing the reset button of the OAP module has the same effect. The device can still identify and
control the OAP module after the module starts up again.
Restrictions and guidelines
Resetting an OAP module might cause a service outage. To avoid service data loss, close the
operating system of an OAP module before resetting the module.
Procedure
To reset an OAP module, execute one of the following commands in user view:
In standalone mode:
oap reboot system system-name
In IRF mode:
oap reboot slot slot-number [ system system-name ]