5

Maintenance and troubleshooting

Power supply failure

Symptom

The status LED on a power supply is not steady green (active state) or flashing green (standby
state).
You can use the status LED on a power supply to identify a power supply failure. For more
information about the status LED on a power supply, see H3C PSR450 Power Module Series User
Manual.

Solution

To resolve the issue:
1.
Verify that the power cord is correctly connected.
2.
Verify that the power source is as required by the power supply.
3.
Verify that the operating temperature of the switch is in an acceptable range and good
ventilation is provided for the power supply.
4.
If the issue persists, contact the H3C Support
To replace a power supply, see

Fan tray failure

CAUTION:
If more than one fan tray fails during the switch operation, do not remove the failed fan trays
simultaneously. Replace the fan trays one by one and finish replacing each fan tray within 3 minutes.
Symptom
The status LED on a fan tray is flashing and the system outputs a message that indicates a fan tray
failure.

Solution

See
"Installing and removing a fan

Configuration terminal display issues

No display on the configuration terminal

Symptom
The configuration terminal does not have display when the switch is powered on.
"Installing and removing a power
tray" to replace the failed fan tray.
5-1
supply."