Type
Use
Placing
Volume
Voltage
Protection grade
Heating power
Heater type
Current input
Heat-up time from 15 ºC to 65 ºC
Standby energy consumption
at 65 ºC
Water connection
Nominal operating pressure
Integrated safety and regulator
elements
Other protection
Contact protection rating
Main regulations applicable to the
product
Storage and transport requirements
10. TECHNICAL DATA
Z30ErP Z50ErP Z80ErP Z100ErP Z120ErP Z150ErP Z200ErP
Closed system hot water storage container
[l]
30
50
[V]
[W]
[A]
[h]
1
1,8
0,77
0,89
[Wh/24h]
[MPa]
Temperature regulator, temperature limiter, combined
Corrosion protection with active anodes
Wall mounted vertical
80
100
120
230V / 50 Hz
IPX4
1800
pipe radiator
8
2,8
3,5
4,2
1
1,3
1,5
G1/2
0,6
safety valve
I .
EN 60335-1, EN 60335-2-21
EN 60721-3
EN
150
200
2400
11
5,3
5,3
1,7
1,56
3 2 7