Panel Configuration - Mitsubishi LE-40MTA-E Instruction Manual

Table of Contents

Advertisement

1.2 Panel configuration

The figure below shows the configuration of the panel of the tension controller LE-40MTA-E.
(5)
(6)
(4)
-E
(3)
OUTP UT
ON/ OFF
CURS OR
(2)
POWER
ENTE R
ON
(1)
INC/ DE C
OFF
CANCE L
(25)
(21)
(24)
(22)
(23)
1. POWER switch and OUTPUT ON / OFF switch
Turn on the POWER switch and the OUTPUT ON/OFF switch to light the LEDs provided on the upper
portion of the both switches.
(Note) Use OUTPUT ON/OFF switch or OUT REMOTE input without using the POWER
switch when the output is turned on and off.
2. DISPLAY SELECTOR switch
The monitored operating tension value is always displayed in the bar graph on the upper right of the
screen.
Under the bar graph, the operating tension or control output is displayed in numeric.
The control output or the operating tension is displayed on the seven-segment display in the same way.
The type of contents displayed is changed every time the Tension/Output selector switch is pressed. The
type of contents displayed on the seven-segment display is indicated by the LED provided on the left
side of the selector switch.
The unit of tension (
3. Automatic operation ( Basic operation )
When the AUTO switch is pressed, the unit performs automatic oper-
ation. However, automatic control is not performed if the operation/
stop input is not turned on.
The tension set value changes from 0 to full scale value in accor-
dance with the scale of the tension set trimmer of 0 to 10.
The full scale tension is set in the initial setting.
When the taper tension is controlled in accordance with the reel diam-
eter, the tension set value subtracted by the taper tension is regarded
as actual target tension and used during automatic control.
4. Manual operation
When the MANUAL switch is pressed, manual operation is available.
The control output of 0
manual torque set trimmer 0
vo mode and the powder mode.)
(7)
MONITOR
S ELE CT
MODE
AUTO
MANUAL
TE NS ION S E T
MANUAL S ET
P AGE
(20)
(14)
(19)
(17)
(16)
(13)
(18)
(15)
(12)
• Allowable power switch cycles : 20,000 times
×
10N or N) is specified by the setting of the parameter.
~
100% can be obtained with the scale of the
~
10. (The output is 0
(1) : POWER switch
(2) : Power LED
(8)
(3) : Output ON/OFF switch
(9)
(4) : Output ON/OFF LED
(5) : LCD display
(6) : Bar graph
(10)
Upper :Tension monitor (%)
Lower :Target tension (%)
(11)
(7) : Scale
(8) : Seven-segment display
(9) : Unit LED
(10) : DISPLAY SELECTOR
Tension and output are
selected alternately.
Selection of kgf or N is
set by the parameter.
~
5V both in the ser-
3
(11)
: Door open screw
(12)
: MANUAL mode switch
(13)
: Manual mode LED
(14)
: Manual torque set
trimmer
(15)
: AUTO mode switch
(16)
: Automatic mode LED
(17)
: TENSION SET trimmer
(18)(19) : Screen scroll keys
(20)(21) : Cursor contorol keys
(22)(23) : Numeric input keys
(24)
: CANCEL key
(25)
: ENTER key
Full scale tension
0
2
4
6
8
10
Left
Trimmer
Right
Tension set
2
4
10
0
6
8
Left
Trimmer
Right
Manual set

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents