Product Name: Double Blow Blocker
Part #: 11002; 11003; 11004; 11012
Instruction Manual
Do not throw away these instructions!
Read and understand these instructions before using equipment!

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 11002 and is the answer not in the manual?

Questions and answers

Summary of Contents for Guardian Fall Protection 11002

  • Page 1 Product Name: Double Blow Blocker Part #: 11002; 11003; 11004; 11012 Instruction Manual Do not throw away these instructions! Read and understand these instructions before using equipment!
  • Page 2: Table Of Contents

    Notes Introduction Thank you for purchasing a Guardian Fall Protection Double Blow Blocker Self-Retracting Lifeline (SRL). This manual must be read and understood in its entirety, and used as part of an employee training program as required by OSHA or any applicable state agency.
  • Page 3: Applicable Safety Standards

    Applicable Safety Standards When used according to instruction specifications, this product meets or exceeds all applicable OSHA 1926 Subpart M, OSHA 1910, ANSI Z359.14-2012, and ANSI A10.32-2012 standards for fall protection. Applicable standards and regulations depend on the type of work being done, and also might include state regulations if applicable.
  • Page 4 The analysis of the workplace must anticipate where workers will be performing their duties, the routes they will take to reach their work, and the potential and existing fall hazards they may be exposed to. Fall protection equipment must be chosen by a Competent Person. Selections must account for all potential hazardous workplace conditions.
  • Page 5: Maintenance, Cleaning, And Storage

    130-310 lbs. Maintenance, Cleaning, and Storage Repairs to SRLs can only be made by a Guardian Fall Protection representative or an entity authorized by Guardian. Contact Guardian for all maintenance and repair needs at: 1-800-466-6385. If a SRL fails inspection in any way, immediately remove it from service, and contact Guardian to inquire about its return or repair.
  • Page 6: Inspection

    Inspection KEEP INSTRUCTIONS AVAILABLE FOR REFERENCE. Record date of first use. Prior to EACH use, inspect SRLs for deficiencies, including, but not limited to, corrosion, deformation, pits, burrs, rough surfaces, sharp edges, cracking, rust, paint buildup, excessive heating, alteration, broken stitching, fraying, bird-caging, and missing or illegible labels. IMMEDIATELY remove SRL from service if defects or damage are found.
  • Page 7: Limitations

    Limitations FALL CLEARANCE CALCULATION Fall Clearance: There must be sufficient clearance below the anchorage connector to arrest a fall before the user strikes the ground or an obstruction. When calculating fall clearance, account for a MINIMUM Lanyard length (6’ total) 3’...
  • Page 8: Components And Specifications

    Components and Specifications Made from galvanized steel, polyester, and stainless steel OR aluminum components. Part # Length Description 11002 6’ Double Blow Blocker Web SRL w/High Strength Aluminum Snap Hooks 11003 6’ Double Blow Blocker Web SRL w/High Strength Aluminum Rebar Hooks 11004 6’...
  • Page 9: Installation And Use

    Installation and Use Double Blow Blockers MUST NEVER be used in Leading Edge (LE) applications. No free fall is allowed. ALWAYS avoid lifeline contact with sharp or abrasive edges and surfaces. In Fall Arrest applications, anchorage connection point must always be at or above harness dorsal D-ring. 1.
  • Page 10: Labels

    Mfg. Date (mo/yr) applications. Design, installation and utilization of HLLs must be supervised by a Qualified Person. _______/_______ _______/_______ HS Alum. Snap Hooks HS Alum. Rebar Hooks 11002 11003 HS Steel Snap Hooks HS Steel Rebar Hooks 11004 11012 www.guardianfall.com...
  • Page 11: Inspection Log

    Inspection Log User must inspect prior to EACH use. Competent Person must complete formal inspection at least EVERY month. Competent Person to inspect and initial inspection log and SRL inspection grid label. Date of first use: __________________. Product lifetime is 5 years from date of first use, or, if not recorded, from date of manufacture, as long as it passes pre-use and Competent Person inspections.