System Validation and Reconfiguration Procedures After Hardware
Upgrade from rp34x0
The system board upgrade part is configured at the factory with default product, serial and UUID IDs. After
replacing the system board, factory default ID values must be overwritten with actual system values. In
rp34x0 machines, the product, serial and UUID actual IDs must be entered manually.
Step 1. Power on the system.
a. Reconnect AC power to rear panel connectors.
b. Press the front panel power switch to power on the server.
Step 2. Restore product, serial and UUID IDs.
a. Type y when prompted to change the system IDs.
Do you want to set the system IDs (can be set at the shell using: sysset)?
(y/[n])
b. Slide the pull tab out of its location in the slot between the power supply and disk drives.
c. Enter UUID, product and serial ID values located on the pull tab label.
Please enter UUID (. to abort)
UUID: 162D4BA1-4D67-11D8-881B-E20562B8C81F
Please enter product number (. to abort)
Product Number: AB459A
Please enter serial number (. to abort)
Serial Number: SGH4414201
d. Type y when prompted to set the system IDs to listed values.
NOTE
The system IDs will be set to the following values:
UUID: 162D4BA1-4D67-11D8-881B-E20562B8C81F
Product Number: AB459A
Serial Number: SGH4414201
Set the system IDs to the above values?
(y/n)
e. Verify successful system ID restoration.
New system ID values were set successfully.
2 0 0x0002F2 0x0000000000000000 Set system IDs to valid values
0 0 0x0002B9 0x0000000000000013 EFI POST code
Step 3. Boot the machine to EFI.
Step 4. Verify system board installation.
a. Enter the info sys command. Verify that the newly installed system board is recognized by the
system. Below is an example of the info sys command output following a successful upgrade:
Chapter 1

System Validation and Reconfiguration Procedures After Hardware Upgrade from rp34x0

Ensure system ID values listed on the screen output match values on the pull
tab.