Specifications - Omron D4DS Manual

Safety-door switch
Table of Contents

Advertisement

D4DS

Specifications

Approved Standard Ratings
TÜV and BIA (EN60947-5-1)
Utilization category
Rated operating current (I
)
e
Rated operating voltage (U
e
Note: Use a 10-A fuse type gl or gG as a short-circuit protection device that conforms to IEC269.
UL (UL508/CSA C22.2 No.14)
A600
Rated voltage
Ca y cu e
Carry current
120 VAC
10 A
240 VAC
480 VAC
600 VAC
Characteristics
Degree of protection (see note 1)
Life expectancy (see note 2)
Operating speed
Contact gap
Operating frequency
Positive opening force (see note 3)
Positive opening travel (see note 3)
Insulation resistance
Contact resistance
Dielectric strength
Rated insulation voltage (U
Conditional short-circuit current
Short-circuit protective device (SCPD)
Switching overvoltage
Pollution degree
(operating environment)
Conventional enclosed thermal current
(I
)
the
Protection against electric shock
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Weight
Note: 1. Although the Switch casing resists dust, oil, and water, make sure that the keyhole on the head is free from dust, oil, water, and
chemical, otherwise the D4DS may wear out, break, or malfunction.
2. Life expectancy values are calculated at an operating temperature of 5 C to 35 C, and an operating humidity of 40% to 70%. Con-
tact your OMRON sales representative for more detailed information on other operating environments.
3. These figures are minimum requirements for safe operation.
AC-15
2 A
)
400 V
Make
60 A
30 A
15 A
12 A
IP65 (EN60947-5-1)
Mechanical: 1,000,000 operations min.
Electrical:
150,000 operations min.
0.1 m/s to 0.5 m/s
2 x 2.0 mm min.
30 operations/minute min.
58.84 N min.
10 mm min.
100 MΩ min. (at 500 VDC) between terminals of same polarity, between terminals of
different polarity, between each terminal and ground, and between each terminal and
non-current-carrying metal part
25 mΩ max. (initial value)
U
4 kV between terminals of same polarity, between terminals of different polarity, and
imp
between each terminal and non-current-carrying metal part (EN60947-5-1)
)
400 V (EN60947-5-1)
i
100 A (EN60947-5-1)
10 A, fuse type gI or gG (IEC269)
1,500 V max. (EN60947-5-1)
3 (EN60947-5-1)
10 A (EN60947-5-1)
Class II (double insulation)
Malfunction: 10 to 500 Hz, 0.65-mm single amplitude with an imposed acceleration of
2
100 m/s
max.
Destruction: 1,000 m/s
Malfunction: 300 m/s
Operating:
–30 C to 70 C (with no icing)
Operating:
95% max.
Approx. 76 g (for D4DS-15FS)
Current
Break
6 A
7,200 VA
3 A
1.5 A
1.2 A
2
min.
2
min.
D4DS
Volt-amperes
Make
Break
720 VA
3

Advertisement