The Provisioning Options Screen is illustrated in
Figure 12. Provisioning may be viewed by the
HTU-C but may not be changed. Provisioning
changes may only be implemented through the
Nx64.
_____________________________________________________
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|_____________________________________________________|
NOTE: Provisions can not be changed at the Nx64 HTU-R. ESF or SF
Type "M" to return to the Main Menu.
61245023L1-5B
PROVISIONING
PROVISIONS
------------------------------------------
1.
DSX-1 LINE BUILDOUT
2.
DSX-1/DS1 LINE CODE
3.
DSX-1/DS1 FRAMING
4.
LOOPBACK TIMEOUT
5.
DS1 OUTPUT LEVEL
6.
NIU LOOPBACK
7.
ALARM
8.
DS0 BLOCKING:
00000000 00000000 00000000
CHANNELS
1
"X" INDICATES A BLOCKED CHANNEL.
framing formats may be provisioned from the HTU-C. All DTE
port configuration must be done from the front panel.

Figure 12. Provisioning Options Screen

TROUBLESHOOTING DISPLAY
_____
|HTU-C|
|
|
|
|
--->|
|<===========================>|
|
|
NET |
|
|
|
<---|
|<===========================>|
|
|
|
|
|_____|
Press "M" for Main Menu.

Figure 13. Troubleshooting Screen

Section 61245023L1-5B, Issue 2
The Troubleshooting Display Screen, illustrated in
Figure 13, graphically depicts an HDSL circuit.
The unit reviews red, yellow, and blue alarm
conditions in the circuit to automatically predict
where a fault is located. Once a fault location is
suspected, the corresponding portion of the circuit
on the screen is highlighted and a message
describing the failure will appear.
|
CURRENT SETTINGS
|
|
=
0-133 FEET
|
=
B8ZS
|
=
ESF
|
=
NONE
|
=
N/A ON Nx64 HTU-R |
=
ENABLED
|
=
N/A ON Nx64 HTU-R |
|
|
|
24
|
|