Download Print this page

Maxitrol GV60 Advanced Troubleshooting page 8

Gas valve

Advertisement

Low Battery Receiver
When the receiver battery power is low, the GV60 system shuts off the fire and pilot.
f i r e - p a r t s . c o m
Five Day Shut Off
(CSA version)
The system shuts off the fire and pilot if there is no change in flame height for 5 days.
Backup Batteries
If the mains power should fail, the receiver automatically goes to battery power for all functions except the light and fan.
Second Thermocouple Shut Off
Second Thermocouple Option: The system shuts off the fire when the main burner does not completely ignite
approximately 20 seconds after ignition or after pushing the large flame button.
NOTE: If there is a failure due to the second thermocouple not receiving a signal, there is a 2-minute waiting period prior to
the next ignition sequence. This is to allow for the gas in the system to dissipate.
GV60 System Features
© 2013, Maxitrol Company