Advertisement

Quick Links

GV60 Bidirectional Control System
for use with Symax
Installation and
Operating Instructions
INSTALLATION INSTRUCTIONS UPON REQUEST
Application ................................................................................. 3
Components ............................................................................. 3
Technical Specifications ........................................................... 4
Mounting Positions .................................................................... 5
Gas Connections ...................................................................... 5
Perform Gas Leak Test ............................................................. 6
Wiring ........................................................................................ 6
▪ Basic .................................................................................... 8
▪ Additional Function .............................................................. 9
▪ 2
Thermocouple Option .................................................. 10
▪ myfire App Setup ............................................................... 12
Knob Settings ......................................................................... 13
Adjustment .............................................................................. 13
Final Check ............................................................................. 14
General Notes ......................................................................... 15
myfire App Setup .................................................................... 15
4-SYMBOL ..............................................................................17
Setting Fahrenheit or Celsius ..................................................17
Setting the Time .......................................................................17
Child Proof ................................................................................17
Manual Mode ...........................................................................17
Designated Low Fire and High Fire .........................................18
Countdown Timer ....................................................................18
myfire App ................................................................................18
6-SYMBOL ..............................................................................19
Setting Fahrenheit or Celsius ..................................................19
Setting the Time .......................................................................19
Child Proof ................................................................................19
Manual Mode ...........................................................................19
Designated Low Fire and High Fire .........................................20
Countdown Timer ....................................................................20
Modes of Operation .................................................................21
R
Handsets and myfire
©
R
App
©
Thermostatic Mode ..................................................................21
Program Mode .........................................................................21
myfire App ............................................................................... 22
8-SYMBOL ..............................................................................23
Setting Fahrenheit or Celsius ..................................................23
Setting the Time .......................................................................23
Child Proof ...............................................................................23
Manual Mode ...........................................................................23
Designated Low Fire and High Fire .........................................24
Countdown Timer ....................................................................24
Modes of Operation .................................................................25
Thermostatic Mode ..................................................................25
Program Mode .........................................................................25
Auxiliary Feature (2nd Burner Feature) ....................................26
Eco Mode .................................................................................26
myfire App ................................................................................26
10-SYMBOL ............................................................................27
Setting Fahrenheit or Celsius ..................................................27
Setting the Time .......................................................................27
Child Proof ................................................................................27
Manual Mode ...........................................................................27
Designated Low Fire and High Fire .........................................28
Countdown Timer ....................................................................28
Modes of Operation .................................................................29
Thermostatic Mode ..................................................................29
Program Mode .........................................................................29
Auxiliary Feature (2nd Burner Feature) ................................... 30
Eco Mode ................................................................................ 30
Circulating Fan Operation ....................................................... 30
Light / Dimmer Operation ..........................................................31
myfire App ................................................................................31
TOUCHPAD / WALL SWITCH ..................................................32
SWITCH PANEL.......................................................................32
Manual Operation ....................................................................33
To Turn off Gas to Appliance ...................................................33
Automatic Turn Down to Pilot ...................................................33
Automatic Shut Off ..................................................................33
1 / 33

Advertisement

Table of Contents
loading

Summary of Contents for Maxitrol GV60

  • Page 1: Table Of Contents

    GV60 Bidirectional Control System for use with Symax Handsets and myfire © © Installation and Operating Instructions INSTALLATION INSTRUCTIONS UPON REQUEST Thermostatic Mode ..............21 Program Mode .................21 Application ................. 3 myfire App ................22 Components ................3 Technical Specifications ............4 8-SYMBOL ................23...
  • Page 2: Final Check

    IMPORTANT SAFETY INFORMATION FOR OEM USE ONLY IMPORTANT SAFETY INFORMATION Read these instructions carefully and completely before installing or operating. Failure to follow them could result in a fire or explo- sion causing property damage, personal injury, or loss of life. Service and installation must be performed by a trained / experienced service technician.
  • Page 3: Wiring

    OPERATING INSTRUCTIONS FOR OEM USE ONLY OPERATING INSTRUCTIONS GENERAL NOTES Activate Functions 1. Install batteries. All icons are displayed and fl ashing. NOTICE 2. To activate a function, press the relevant button and hold for 10 sec. Wiring of valve and receiver must be completed before starting 3.
  • Page 4 OPERATING INSTRUCTIONS FOR OEM USE ONLY NOTICE To connect myfire Wi-Fi Box to Wi-Fi Router (Home Network), make sure: ▪ Home Network is available. ▪ Home Network name and password are correct. ▪ SSID of the Wi-Fi Router is not hidden. ▪...
  • Page 5: 4-Symbol

    Day flashes. BEFORE OPERATING 2. Press button to select a num- 1. Make sure MANUAL knob on the GV60 valve is in the ON, ber to correspond with the day of the full counterclockwise position. week (e. g.   = Monday, = Tuesday, 2.
  • Page 6: Designated Low Fire And High Fire

    OPERATING INSTRUCTIONS FOR OEM USE ONLY ▪ Press button (One Button Ignition) ▪ To go to high fire, double-click but- button simultaneously ton. is displayed. (Two Button Ignition) until two short beeps and a blinking series of lines confirms the start sequence has be- gun;...
  • Page 7: 6-Symbol

    OPERATING INSTRUCTIONS FOR OEM USE ONLY 6-SYMBOL Child Proof Time Signal Indicator Thermostatic Mode Battery Status Countdown Timer Fahrenheit or Celsius Program Mode Temperature Figure 27: 6-symbol Display SETTING FAHRENHEIT or CELSIUS CHILD PROOF To change between °C and °F, press buttons simultaneously.
  • Page 8: Manual Mode

    NOTICE NOTE: Backlight must be on for high fire and low fire double-click operation. BEFORE OPERATING 1. Make sure MANUAL knob on the GV60 valve is in the ON, ▪ To go to low fire, double-click but- full counterclockwise position.
  • Page 9: Modes Of Operation

    OPERATING INSTRUCTIONS FOR OEM USE ONLY MODES of OPERATION PROGRAM MODE Thermostatic Mode The room temperature is measured and Press button. or , compared to the set temperature. The displayed. flame height is then automatically ad- justed to achieve the set temperature.  ...
  • Page 10: Myfire App

    OPERATING INSTRUCTIONS FOR OEM USE ONLY MYFIRE APP selected NOTICE ON TIME SETTING (PROGRAM 1): displayed, is displayed Before the App can be used, the myfire Wi-Fi Box must be wired shortly, and hour flashes. and plugged into mains power according to myfire App setup 8.
  • Page 11: 8-Symbol

    OPERATING INSTRUCTIONS FOR OEM USE ONLY 8-SYMBOL Child Proof Time Signal Indicator Thermostatic Mode Battery Status Countdown Timer Fahrenheit or Celsius Program Mode Eco Mode Temperature Auxiliary Feature Figure 28: 8-symbol Display SETTING FAHRENHEIT or CELSIUS CHILD PROOF To change between °C and °F, press buttons simultaneously.
  • Page 12: Manual Mode

    NOTICE NOTE: Backlight must be on for high fire and low fire double-click operation. BEFORE OPERATING 1. Make sure MANUAL knob on the GV60 valve is in the ON, ▪ To go to low fire, double-click but- full counterclockwise position.
  • Page 13: Modes Of Operation

    OPERATING INSTRUCTIONS FOR OEM USE ONLY MODES of OPERATION PROGRAM MODE Thermostatic Mode The room temperature is measured and Press button. or , compared to the set temperature. The displayed. flame height is then automatically ad- justed to achieve the set temperature.  ...
  • Page 14: Auxiliary Feature (2Nd Burner Feature)

    OPERATING INSTRUCTIONS FOR OEM USE ONLY AUXILIARY FEATURE (2ND BURNER FEATURE) selected ON TIME SETTING (PROGRAM 1): The latching solenoid valve will open automatically after ignition displayed, is displayed or after switching the system off, so that the maximum flow of shortly, and hour flashes.
  • Page 15: 10-Symbol

    OPERATING INSTRUCTIONS FOR OEM USE ONLY 10-SYMBOL Child Proof Time Signal Indicator Thermostatic Mode Battery Status Countdown Timer Fahrenheit or Celsius Light Program Mode Eco Mode Temperature Auxiliary Feature Figure 29: 10-symbol Display SETTING FAHRENHEIT or CELSIUS CHILD PROOF To change between °C and °F, press buttons simultaneously.
  • Page 16: Manual Mode

    NOTICE NOTE: Backlight must be on for high fire and low fire double-click operation. BEFORE OPERATING 1. Make sure MANUAL knob on the GV60 valve is in the ON, ▪ To go to low fire, double-click but- full counterclockwise position.
  • Page 17: Modes Of Operation

    OPERATING INSTRUCTIONS FOR OEM USE ONLY MODES of OPERATION PROGRAM MODE Thermostatic Mode The room temperature is measured and Press button. or , compared to the set temperature. The displayed. flame height is then automatically ad- justed to achieve the set temperature.  ...
  • Page 18: Auxiliary Feature (2Nd Burner Feature)

    OPERATING INSTRUCTIONS FOR OEM USE ONLY AUXILIARY FEATURE (2ND BURNER FEATURE) SELECTED ON TIME SETTING (PROGRAM 1): The latching solenoid valve will open automatically after ignition displayed, is displayed or after switching the system off, so that the maximum flow of shortly, and hour flashes.
  • Page 19: Light / Dimmer Operation

    OPERATING INSTRUCTIONS FOR OEM USE ONLY LIGHT / DIMMER OPERATION Press button ( displayed). Light is on at preset level. OFF: Press button ( disappears). SETTING: 1. Press button and hold until flash- 2. To adjust light between 20…100 % press button.
  • Page 20: Touchpad / Wall Switch

    OPERATING INSTRUCTIONS FOR OEM USE ONLY SWITCH PANEL TOUCHPAD / WALL SWITCH Increase flame height A) Increase flame height ON/OFF B) ON/OFF Decrease flame height C) Decrease flame height Figure 30: Touchpad / Wall Switch Figure 31: Switch Panel To Turn ON Appliance To Turn ON Appliance ▪...
  • Page 21: Manual Operation

    OPERATING INSTRUCTIONS FOR OEM USE ONLY MANUAL OPERATION TO TURN OFF GAS TO APPLIANCE (Only possible, when MANUAL knob is used) 1. Place ON / OFF switch (if equipped) in O (OFF) position. Access to the pilot burner is only required for ignition with a 2.
  • Page 22 Exclusive Distributor Europe Exclusive Distributor North America for Maxitrol Company for Mertik Maxitrol Maxitrol Company Mertik Maxitrol GmbH & Co. KG 23555 Telegraph Rd., PO Box 2230 Warnstedter Str. 3, 06502 Thale Southfield, MI 48037-2230 GERMANY Tel: + 49 3947 400-0...

Table of Contents