Download Print this page

Maxitrol GV60 Advanced Troubleshooting page 51

Gas valve

Advertisement

f i r e - p a r t s . c o m
Troubleshooting the GV60
Testing the Electronics
TEST: Take a mV reading at the yellow terminal.
PROCEDURE: Connect "+" test probe on yellow wire.
Connect "-" test probe to ground,
e.g. valve body or appliance chassis.
Subtract mV reading from test on the
red wire (see previous slide) from current
reading on the yellow wire.
RESULT: The difference is the power being consumed
by the receiver.
Connect "+" test probe on yellow wire
© 2013, Maxitrol Company
51