TEST: Verify that the motor is getting power.
PROCEDURE: Connect "+" test probe on brown wire.
Connect "-" test probe to ground, e.g. valve
body or appliance chassis.
Push UP FLAME button on the handset.
RESULT: The reading should be 5-6 Volts and motor
should move. If there is no motor movement,
the motor may be damaged. Replace motor
(motor kits available).
f i r e - p a r t s . c o m
Connect "+" test probe on the brown wire.
Troubleshooting the GV60
Verifying Motor Operation
© 2013, Maxitrol Company