Maxitrol GV60 Advanced Troubleshooting page 47

Gas valve

Advertisement

TEST: Manually light the fireplace to verify the gas supply
is sufficient.
PROCEDURE: Turn MANUAL knob to MAN.
Insert small tool and depress the plunger.
Light pilot and hold the plunger for 10 seconds.
Turn knob back to ON.
RESULT: If the manual light is successful, test the electronics.
f i r e - p a r t s . c o m
Troubleshooting the GV60
Testing the Valve
© 2013, Maxitrol Company
47