SIMATIC RF166C
Operating Instructions, 12/2019, C79000-G8976-C578-01
Error description
Address error
The address range of the transponder has been exceeded.
Possible causes:
Start address of the command start has been incorrectly set.
Wrong transponder type
The area to be written to is write-protected.
Initialization error
Transponder is unable to execute the initialization command
Possible causes:
Transponder is defective.
The transponder memory is full.
Error in transponder memory
The transponder has never been written to or has lost the contents of its memory due to battery
failure.
Possible causes / action to be taken:
Replace the transponder (if the battery bit is set).
Re-initialize the transponder.
ECC error
The transponder in the antenna field does not have the expected UID / EPC ID or has no UID /
EPC ID.
The command is not supported by the transponder.
The transponder is read/write-protected.
The transponder is not responding.
The transponder password is incorrect. Access is denied.
The verification of the written transponder data has failed.
Possible causes:
Transponder is defective.
Transponder is in the limit area.
General transponder error
The transponder has too little power to execute the command.
Possible causes:
Transponder is in the limit area.
Service and maintenance
10.2 Error messages