Service and maintenance
10.1 Diagnostics
10.1.1

Diagnostics via the LED display

The following figure shows details of the LEDs of the RF166C.
Figure 10-1
124
Status LED display
RUN/STOP (RUN)
ERROR (ERROR)
MAINTENANCE (MAINT)
Reader LED display
PRESENCE (PRE)
ERROR (ER)
Ethernet LED display
LINK
PROFIBUS LED display
DP
LED displays of the RF166C communication module
Indicates whether the CM is ready for operation.
Indicates whether an error has occurred.
Shows whether the communication module needs mainte-
nance.
Indicates whether there are one or multiple transponders in
the antenna field.
Indicates whether communication with the reader is taking
place and whether a reader error has occurred.
Shows whether an Ethernet connection is present.
Shows whether a PROFIBUS connection via the PROFIBUS
interface is available.
Operating Instructions, 12/2019, C79000-G8976-C578-01