Maintenance; Maintenance And Cleaning The Unit; Fuse Replacement - ProLights DIGIDRIVERIP User Manual

Hide thumbs Also See for DIGIDRIVERIP:
Table of Contents

Advertisement

Available languages

Available languages

DIGIDRIVERIP - DIGISTRIPIP50 - DIGISTRIPIP100
18

- 5 - MAINTENANCE

5.1 MAINTENANCE AND CLEANING THE UNIT

• Make sure the area below the installation place is free from unwanted persons during setup.
• All screws used for installing the device and any of its parts should be tightly fastened and should not
be corroded.
• Housings, fixations and installation spots (ceiling, trusses, suspensions) should be totally free from any
deformation.
• The main cables must be in impeccable condition and should be replaced immediately even when a
small problem is detected.
To maintain optimum performance and minimize wear, you should clean this product frequently. Usage
and environment are contributing factors in determining the cleaning frequency.
As a rule, clean this product at least twice a month. Dust build-up reduces light output performance and
can cause overheating. This can lead to reduced light source life and increased mechanical wear.
Cleaning the unit:
• Unplug the product.
• Wait until the product is at room temperature.
• Use a vacuum (or dry compressed air) and a soft brush to remove dust collected on the external vents
and accessible internal components.
• Clean all external surfaces with a mild solution of non-ammonia glass cleaner or isopropyl alcohol.
• Apply a solution directly to a soft, lint-free cotton cloth or a lens cleaning tissue.
NOTE - Do not open this product for cleaning or servicing.

5.2 FUSE REPLACEMENT

1. Disconnect this product from the power outlet.
2. Remove the safety cap by a screwdriver.
3. Replace the blown fuse with a fuse of the exact same type and rating.
4. Install the safety cap, and reconnect power.
Fig.7

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Digistripip50Digistripip100

Table of Contents