Triax Output Voltage Protect Operation Check - Sony CCU-700A Maintenance Manual

Camera control unit
Hide thumbs Also See for CCU-700A:
Table of Contents

Advertisement

3-12.
TRIAX Output Voltage Protect
Operation Check
Preparation:
• Connect the CCU-700A/700AP to a video camera with
TRIAX cable.
Check:
1. When the power switches of CCU-700A/700AP and
video camera is turned on, check that the LEDs of CCU-
700A/700AP and video camera light up according to the
following table.
Switch
CCU-700A
BVP
MAIN
CAMERA
POWER
ON
OFF
OFF
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON *2
*1: When video camera BVP-700/700P is connected.
*2: The condition that the AU board of the video camera is disconnected.
CCU-700 A
CCU-700AP
LED
CCU
MAIN
CAMERA
SHORT
lights up
goes out
goes out
lights up
goes out
goes out
lights up
lights up
goes out
lights up
lights up
goes out
lights up
goes out
goes out
MAIN LED
SHORT LED
OPEN LED
CAMERA LED
CAMERA SWITCH
MAIN SWITCH

3-12. TRIAX Output Voltage Protect Operation Check

BVP
OPEN
POWER *1
lights up
goes out
goes out
lights up (red)
lights up
goes out
goes out
lights up (green)
lights up
lights up (red)
3-53

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ccu-700ap

Table of Contents