1-3. Installation
1-3-1. Installation Conditions
5 dC to +40 dC
Operating temperature:
-20 dC to +50 dC
Storage temperature:
Humidity:
No condense
• Install the unit in a location as dry and well-ventilated as
possible.
• Do not install the unit in the following conditions.
High temperature room or near the heat source
Excessive dust or mechanical vibration
Intense magnetic and electric field
A place subjected to direct sunlight or strong light
Note on installation : Set the voltage selecters accord-
ing to a destination.
As for the setting, refer to "2-1-6.
Replacement of Power Unit".
1-3-2. Outside Dimension
481
465
424
CABLE
DYNAMIC
MIC
ALARM
SHORT OPEN
OFF
CARBON
MAIN
CAMERA
POWER
POWER
INTERCOM
I
I
O
O
CCU-700A(UC)
CCU-700AP(CE)
http://getMANUAL.com
CAMERA CONTROL UNIT
(Unit : mm)
1-3-3. Installation of BKP-7312
1. Set the S250-1 switch on the BKP-7312 to OFF.
2. Remove the six screws (B3x5) and then remove the
rear panel.
3. Disconnect the connector CN4 on the CN-1014 board
and the connector CN3 on the CN-1049 board.
n
When disconnecting the flexible card wires, refer to
"2-1-3. Disconnecting/Connecting of Flexible Card
Wire."
Flexible card wires
MB-563 board
CN-1014 board
CN4
B3 × 5
Rear panel
4. Connect the two coaxial cables.
RET1/CN-1015 board — CN1/BKP-7312
RET2/CN-1015 board — CN2/BKP-7312
n
Removing the CN-1015 board makes cable connec-
tions easier. The CN-1015 board is secured with four
screws from the rear panel.
When installing the board, apply locking compound to
the four screws.
BKP-7312
CN2
CN1
Coaxial cable
RET1
1-3. Installation
B3 × 5
CN-1049 board
CN3
B3 × 5
A side
CN-1015 board
RET2
B3 × 5
B3 × 5
1-7