• S1102 (SEQ +/-)
Select "+" or "-" according to a waveform monitor in
use.
+ : NPN open collector output
- : PNP open collector output
Factory-setting is "-".
• S1361 (I ON/OFF)... for CCU-700A
• S1361 (U ON/OFF)... for CCU-700AP
This switch is used for the encoder circuit adjustment.
When the switch is set to "OFF", the I/U signal is not
added to the chroma circuit. Therefore, the composite
video signal (VB or VBS) output from the CCU does not
contain the I/U signal.
Normally set to "ON" (marked position).
• S1362 (Q ON/OFF)... for CCU-700A
• S1362 (V ON/OFF)... for CCU-700AP
This switch is used for the encoder circuit adjustment.
When the switch is set to "OFF", the Q/V signal is not
added to the chroma circuit. Therefore, the composite
video signal (VB or VBS) output from the CCU does not
contain the Q/V signal.
Normally set to "ON" (marked position).
S1361, S1362 Factory setting
• S1501 (NOTCH ON/OFF)...CCU-700AP only
A cross color of the VBS output will be reduced by
turning on the notch filter circuit. To adjust the notch
filter circuit, use controls on the VA board or the MSU-
700 touch panel. And to turn on or off the circuit use the
switch S1501 or the MSU-700 touch panel. "ON"
operation has a priority.
Normally set this switch to "OFF".
• S1891 (H BLKG)
Used to adjust the H blanking width. The pulse width is
factory-set to 10.9 ± 0.2 µs for CCU-700A and to
12.0 ± 0.2 µs for CCU-700AP.
Set according to use.
• S1892 (V BLKG)... CCU-700A only
Used to set the V blanking width to 19H, 20H or 21H.
Factory-setting is "20H". Set according to use.
• S1961 (SC STEP)
Used to adjust the subcarrier phase. One step of this
switch changes 90 degrees. This switch activates only
when the switch S1962 is "LOCAL".
CCU-700A(UC)
CCU-700AP(CE)
http://getMANUAL.com
• S1962 (REMOTE/LOCAL)
• S2031 (SKIN SIGNAL ON/OFF)
Mark
• S2032 (CB SELECT)
This switch selects whether the master setup unit MSU
performs the following adjustments or the CCU-700A
does.
• H and SC phases synchronization with an external
genlock signal
• NOTCH level and width adjustments (CCU-700AP
only)
REMOTE : The master control unit does.
LOCAL
: CCU-700A does using the switch and
controls on the VA-156A/156P board.
S1961(SC STEP)...for SC PHASE adjustment
RV1961(SC FINE)
RV1962(H PHASE)...for H PHASE adjustment
RV1963(H FINE)
RV1501(NOTCH LEVEL)...for NOTCH adjustment
RV1502(NOTCH WIDTH) (CCU-700AP only)
When using a remote control unit of RCP-700 series not
having the above control functions together with the
CCU, be sure to set S1962 to "LOCAL".
Factory-setting is "REMOTE".
When this switch is set to "ON", the I axis signal (skin
signal) is mixed with the color-bar signal output from the
CCU. This skin signal can be monitored by turning on
the CB 3 button in the MSU touch panel. When the
switch S2031 is set to "OFF", the skin signal can not be
monitored even if turning on the CB 3 button of the
MSU.
Factory-setting is "ON".
at color-bar signal output (CB GATE ON)
This switch selects a color-bar signal the CCU outputs.
The following signals can be output.
CCU-700A
: SMPTE, EIAJ, FULL
CCU-700AP : EBU, 95 % CB
Factory-setting is "SMPTE" for CCU-700A and is
"EBU" for CCU-700AP.
1-4. Function of Internal Switch
B/W
SKIN signal
COLOR
1-17