Enter A New Pedal Length; Change Data Sample Rate; Enter Data Trigger Parameter - KEMKRAFT KEI-095A Instructional Manual

3 / 4 / 8 ch. brake pedal travel tester (metric)
Hide thumbs Also See for KEI-095A:
Table of Contents

Advertisement

Enter a new Pedal Length (cm):
1. Turn on the brake tester. Press any key to display the main menu.
2. Press the 2 key to enter the System Setup Menu.
3. Press the 1 key to enter the Test Parameters Menu.
The Test Parameters Menu will be displayed.
4. Press the 1 key to change the pedal length.
5. The display will show the current pedal length. Enter the Four numbers of the new pedal
length on the keyboard. Be sure to enter any leading zeros and the hundreds place decimal
point will be entered automatically.
When the forth number is entered, the display will go back to the Test Menu. The new pedal
length is stored in memory and will remain until it is changed again.

Change Data Sample Rate

1. Press the 2 key to enter the System Setup Menu.
2. Press the 1 key to enter the Test Parameters Menu.
3. Press the 2 key to change the sample rate. The standard default rate is 10 samples per
second with a maximum rate of 50. If the sample rate of 10 is changed to 50 the data
storage time is decreased.

Enter Data Trigger Parameter:

1. Press the 2 key to enter the System Setup Menu. Press the 2 key to enter the Test Options
Menu.
96-005.doc
47650 CLIPPER DR. PLYMOUTH TWP., MICHIGAN 48170 (734) 414-6500
KEMKRAFT
MODEL KEI-095A BRAKE PEDAL TESTER (METRIC)
Test Parameters Menu
1 = Set Pedal Length
2 = Vary Sample Rate
* = ABORT
ENGINEERING, INC.
Page 7 of 16
Revised: 11-NOV-99