Operation; Temperature Setting; Rapid Heat-Up; Cleaning, Care And Maintenance - STIEBEL ELTRON PSH 30 Comfort Universal Operation And Installation

Wall mounted dhw cylinder
Hide thumbs Also See for PSH 30 Comfort Universal:
Table of Contents

Advertisement

Available languages

Available languages

  • ENGLISH, page 14
HTV`.HC
HTV`.HC
4.

Operation

Risk of damage
Only the contractor is permitted to remove the tempera-
ture selector.
4.1

Temperature setting

5
4
3
1 Temperature selector
2 Rapid heat-up button
3 ON/OFF indicator
4 Frost protection setting 7 °C
E Economy setting 40 °C
e Economy setting 60 °C
5 Maximum set temperature
As soon as the water temperature drops below the selected value,
the heating element automatically switches on. The ON/OFF in-
dicator light illuminates until the selected temperature has been
reached.
For low water consumption or very hard water, we recommend a
low temperature setting, as water above approx. 55 °C deposits
limescale.
4.1.1 Holiday and absence
ª If the appliance is not in use for long periods, set it to frost
protection or disconnect it from the power supply, in order to
save energy.
ª For reasons of hygiene, heat up the content of the cylinder
once to above 60 °C before initial use.
4.2

Rapid heat-up

You can increase the output with the rapid heat-up button. A
second heating element is switched on (see chapter „Specification
/ Data table"). The second heating element is switched off when
the selected temperature has been reached.
’TZ+ HB%HV` eC.pVZ<
5.

Cleaning, care and maintenance

ª Never use abrasive or corrosive cleaning agents. A damp
cloth is sufficient for cleaning the appliance.
ª Check the taps regularly. You can remove limescale deposits
at the tap outlets using commercially available descaling
agents.
ª Have the electrical safety of the appliance and the func-
tion of the safety assembly regularly checked by a heating
1
contractor.
ª Have the protective magnesium anode checked by a heating
contractor after the first year. The heating contractor will
then determine the intervals at which it must be checked
thereafter.
ª Regularly activate the safety valve to prevent it from becom-
ing blocked by limescale deposits.
6.

What to do if ...

2
6.1

... the appliance develops faults

%| ù
The water does not
heat up and the ON/OFF
indicator does not il-
luminate.
The water does not heat
up sufficiently and the
ON/OFF indicator illumi-
nates.
The outlet flow rate is
low.
If you cannot remedy the fault, notify your heating contractor. To
facilitate and speed up your enquiry, please provide the serial
number from the type plate (000000 and 0000-00000):

  
|
¼
á V¼ ¼®
There is no power.
Check the fuse/MCB in
your fuse box/distribu-
tion panel.
The temperature is set
Select a higher tempera-
too low.
ture.
The appliance heats,
Wait until the ON/OFF
for example, after large
indicator goes out.
amounts of DHW have
been drawn.
The perlator in the tap or
Clean and/or descale the
shower head is scaled or
perlator or the shower
contaminated.
head.
(12 