Preparing for boiler installation
Use a connection set or connection kit, available as an
accessory, to make the connection on the gas and
water sides.
Fitting accessories
Fit all accessories that are installed at the back of the
boiler (e.g. connection sets).
Preparing connections on site:
Connection set installation instructions
or
Assembly kit installation instructions
410
398
361
320
E
A
D
B
F
C
C
F
B
D
A
E
K
G
80
50
140
Fig. 1
330
220
55
G
C
F
A
B
50
600
Fig. 2
Heating flow R
A
¾
DHW R
B
½
Gas connection R
C
¾
Cold water R
D
½
E
Heating return R
¾
DHW circulation R
F
½
Condensate drain facing backwards into the wall
G
Condensate drain to the side
H
Wiring area
K
D
E
(separate accessory)
Note
Fit safety equipment in accordance with the national
regulations.
!
Please note
Avoid damaging the appliance.
Connect all pipework free of load and torque
stress.
The following diagram shows sample connection sets
for installation on finished walls, with connection to the
top or side.
50
Ø 96
-0,5
Ø 60,5
+0,8
G
40
H
46
Rated heating output
a (mm)
b (mm)
c (mm)
d (mm)
e (mm)
f (mm)
g (mm)
h (mm)
k (mm)
l (mm)
m (mm)
n (mm)
p (mm)
q (mm)
Note
All height dimensions have a tolerance of +7 mm on
account of the adjustable feet.
Preparing for installation
13, 19, 26
35 kW
kW
745
750
972
1172
1027
1227
1082
1302
1137
1337
1191
1391
1247
1447
1302
1562
1437
1637
1466
1666
1465
1665
1526
1726
201
945
950
224