Viessmann Vitodens 222-F Installation And Service Instructions For Contractors page 81

Gas condensing storage combi boiler natural gas and lpg version
Table of Contents

Advertisement

Heating circuit 1, heating circuit 2, heating...
"Display correction of the actual room temperature"
Setting
None
... K
... K
"Recognition, speed-controlled circulation pump"
Setting
Without
With
"Max. speed of speed-controlled heating circuit pump in standard mode"
Setting
... %
... %
"Min. speed of speed-controlled heating circuit pump in standard mode"
Setting
30 %
... %
"Speed setting in reduced mode"
Setting
Minimum speed according to parameter E7 E8:0
Reduced speed according to parameter E9 E8:1
"Speed of speed-controlled heating circuit pump in reduced mode"
Setting
45 %
... %
(cont.)
Explanations
E2:50
With remote control: No display correction of the ac-
tual room temperature
E2:0 to
Display correction
E2:49
to
Display correction
E2:51 to
Display correction +0.1 K
E2:100
to
Display correction +4.9 K
Explanations
E5:0
E5:1
Automatic recognition
Explanations
E6: ...
This value is determined by boiler-specific parameters
E6:0 to
Maximum speed adjustable from 0 to 100 %
E6:100
Explanations
E7:30
E7:0 to
Minimum speed adjustable from 0 to 100 % of the
E7:100
maximum speed
Explanations
Explanations
E9:45
E9:0 to
Speed adjustable from 0 to 100 % of max. speed
E9:100
Parameter level 2
5 K
0.1 K
81