Zq04-06 Side Duct Application (Belt Drive) - York International ZQ Series Installation Manual

Table of Contents

Advertisement

ZQ04-06 Side Duct Application (Belt Drive)

Table 25: ZQ04 (3.0 Ton) Side Duct
CFM
0.2
0.4
RPM
BHP
RPM
BHP
900
n/a
n/a
877
0.25
1000
795
0.21
887
0.29
1100
806
0.25
899
0.34
1200
820
0.31
913
0.39
1300
836
0.37
929
0.45
1400
855
0.43
948
0.52
1500
876
0.50
969
0.58
Medium Static Option with Motor rated at 2.4-hp
High Static Option with Motor rated at 2.4-hp
--
Exceeds recommended Blower speed
1
Blower performance includes gas heat exchangers and 2" filters. See STATIC RESISTANCE table for additional applications. Note:
See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. kW = 0.929
x BHP
Table 26: ZQ05 (4.0 Ton) Side Duct
CFM
0.2
0.4
RPM
BHP
RPM
BHP
1200
893
0.37
976
0.46
1300
910
0.43
993
0.52
1400
931
0.49
1014
0.59
1500
956
0.56
1039
0.66
1600
985
0.64
1067
0.74
1700
1016
0.73
1099
0.82
1800
1051
0.82
1134
0.92
1900
1088
0.93
1171
1.02
2000
1128
1.04
1211
1.14
Medium Static Option with Motor rated at 2.4-hp
High Static Option with Motor rated at 2.4-hp
Field supplied AK41 x 3/4" fixed blower pulley with Motor rated at 2.4-hp
--
Exceeds recommended blower speed
1
Blower performance includes gas heat exchangers and 2" filters. See STATIC RESISTANCE table for additional applications. Note:
See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. kW = 0.929
x BHP
AVAILABLE EXTERNAL STATIC PRESSURE - IWG
0.6
0.8
RPM
BHP
RPM
BHP
RPM
965
0.34
1050
0.44
1133
976
0.38
1061
0.48
1143
988
0.43
1073
0.53
1155
1002
0.48
1087
0.58
1169
1018
0.54
1103
0.64
1185
1036
0.61
1121
0.70
1204
1058
0.68
1143
0.77
1225
AVAILABLE EXTERNAL STATIC PRESSURE - IWG
0.6
0.8
RPM
BHP
RPM
BHP
RPM
1054
0.56
1128
0.66
1199
1071
0.62
1144
0.72
1216
1092
0.69
1166
0.78
1237
1117
0.76
1191
0.85
1262
1145
0.83
1219
0.93
1290
1177
0.92
1251
1.02
1322
1212
1.02
1286
1.11
1357
1249
1.12
1323
1.22
1394
1289
1.23
1363
1.33
1434
Johnson Controls Ducted Systems
1
1.0
1.2
1.4
BHP
RPM
BHP
RPM
BHP
0.54
1213
0.64
1292
0.74
0.58
1224
0.68
1303
0.78
0.63
1236
0.73
1315
0.83
0.68
1249
0.78
1329
0.88
0.74
1265
0.84
1345
0.94
0.80
1284
0.90
1363
1.00
0.87
1305
0.97
1385
1.07
1
1.0
1.2
1.4
BHP
RPM
BHP
RPM
BHP
0.75
1268
0.85
1336
0.94
0.81
1285
0.91
1353
1.00
0.88
1306
0.97
1374
1.06
0.95
1331
1.04
1399
1.14
1.03
1359
1.12
1428
1.21
1.11
1391
1.21
1459
1.30
1.21
1426
1.30
1494
1.40
1.31
1463
1.41
1532
1.50
1.43
1503
1.52
1571
1.61
INSTALLATION MANUAL ZQ SERIES 3 - 5 ton 60 Hertz R-410A
1.6
1.8
RPM
BHP
RPM
BHP
RPM
1371
0.83
1450
0.92
1531
1382
0.87
1461
0.96
1541
1394
0.92
1473
1.01
1553
1407
0.97
1487
1.06
1567
1423
1.03
1503
1.12
1583
1442
1.10
1521
1.19
--
1464
1.17
1543
1.26
--
1.6
1.8
RPM
BHP
RPM
BHP
RPM
1404
1.03
1474
1.12
1545
1421
1.09
1491
1.18
1562
1442
1.15
1512
1.24
1583
1467
1.23
1537
1.31
1608
1496
1.30
1565
1.39
1637
1528
1.39
1597
1.48
--
1562
1.49
1632
1.57
--
1600
1.59
--
--
--
1640
1.70
--
--
--
2.0
BHP
1.01
1.05
1.09
1.15
1.21
--
--
2.0
BHP
1.20
1.26
1.33
1.40
1.47
--
--
--
--
47