Zq04 To 06 High Static Indoor Blower - Without Powered Convenience Outlet - York International ZQ Series Installation Manual

Table of Contents

Advertisement

ZQ04 to 06 High Static Indoor Blower - Without Powered Convenience Outlet

Table 11: ZQ04-06 High Static Indoor Blower - Without Powered Convenience Outlet
Compressor 1
Compressor 2
RLA LRA MCC RLA LRA MCC
208-3-60 10.4
73
16
230-3-60 10.4
73
16
04 (3)
460-3-60
5.8
38
9
575-3-60
3.8 36.5
6
208-3-60 13.7 83.1
21
230-3-60 13.7 83.1
21
05 (4)
460-3-60
6.2
41
10
575-3-60
4.8
33
8
1
Minimum Circuit Ampacity.
2
Dual Element, Time Delay Type.
3
HACR type per NEC.
4
Non-fused Disconnect, Verify on the unit nameplate that the disconnect is properly sized for the application. Units with field
installed electric heat kits may exceed the factory installed disconnect amperage rating.
30
INSTALLATION MANUAL ZQ SERIES 3 - 5 ton 60 Hertz R-410A
Electric Heat Field
Installed Kit 2EK045*
Model kW Stages Amps
None
-
10625
4.9
1.4
5.2
1.1
11125
7.9
11625
12
None
-
10625
6.5
1.4
5.2
1
11125 10.5
11625
16
None
-
10646
6
0.8
2.6
0.5
11146 11.5
11446
14
None
-
0.6
2
0.4
11058
9.2
11458 13.8
None
-
10625
4.9
1.4
5.2
1.1
11125
7.9
11625
12
None
-
10625
6.5
1.4
5.2
1
11125 10.5
11625
16
None
-
10646
6
0.8
2.6
0.5
11146 11.5
11446
14
None
-
0.6
2
0.4
11058
9.2
11458 13.8
Johnson Controls Ducted Systems
-
-
19.6
20
30
1
13.6
23.5
25
30
1
21.9
33.9
35
35
1
33.3
48.1
50
50
-
-
19.6
20
30
1
15.6
26
30
30
1
25.3
38.1
40
40
1
38.5
54.6
60
60
-
-
10.7
15
15
1
7.2
12.3
15
15
1
13.8
20.5
25
25
1
16.8
24.3
25
25
-
-
7.4
15
15
1
8.9
13.6
15
15
1
13.3
19.1
20
20
-
-
23.7
25
35
1
13.6
23.7
25
35
1
21.9
33.9
35
35
1
33.3
48.1
50
50
-
-
23.7
25
35
1
15.6
26
30
35
1
25.3
38.1
40
40
1
38.5
54.6
60
60
-
-
11.2
15
15
1
7.2
12.3
15
15
1
13.8
20.5
25
25
1
16.8
24.3
25
25
-
-
8.6
15
15
1
8.9
13.6
15
15
1
13.3
19.1
20
20
FLA LRA
FLA LRA
20
99
20.7
25
30
21
101
22
99
24.9
25
30
23
101
31
99
35.3
40
40
32
101
44
99
49.5
50
50
46
101
20
101 20.6
25
30
21
104
24
101 27.3
30
30
25
104
35
101 39.4
40
40
36
104
50
101 55.9
60
60
51
104
11
52
11.2
15
15
11
54
11
52
12.9
15
15
12
54
19
52
21.1
25
25
19
54
22
52
24.9
25
25
23
54
7
48
7.8
15
15
8
49
13
48
14.1
15
15
13
49
18
48
19.6
20
20
18
49
23
109 24.8
25
35
25
111
23
109 24.9
25
35
25
111
31
109 35.3
40
40
32
111
44
109 49.5
50
50
46
111
23
111 24.7
25
35
24
114
24
111 27.3
30
35
25
114
35
111 39.4
40
40
36
114
50
111 55.9
60
60
51
114
11
55
11.7
15
15
12
57
11
55
12.9
15
15
12
57
19
55
21.1
25
25
19
57
22
55
24.9
25
25
23
57
9
45
9
15
15
9
45
13
45
14.1
15
15
13
45
18
45
19.6
20
20
18
45

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

ZqeZqg

Table of Contents