Gas Specifications; Seismic Restraints - Warmington SG 700 Installation Instructions Manual

Freestanding square - open gas fire
Table of Contents

Advertisement

GAS SPECIFICATIONS

NOTE : All Test Pressures are tested by a Independent Test Lab
MODEL
LPG
Nominal Pressure kPa
Nominal Injector Size mm
Burner Pressure High kPa
Burner Pressure Low kPa
MJ/h
Flame Effect Output Only
Supply Pipe Size dia—min
Natural Gas
Nominal Pressure kPa
Nominal Injector Size mm
Burner Pressure High kPa
Burner Pressure Low kPa
MJ/h
Flame Effect Output Only
Supply Pipe Size dia—min
Lab. Test No
Lab. Test Dates
ESS Declaration No:

SEISMIC RESTRAINTS

Seismic Restraint
Secure Firebox through
anchor points provided
This is a raised & cantilevered hearth.
See spec for detail.
*Note: If Solid Plastering the Heat Cell Structure, it is recommended to use a Fibreglass Mesh with a Latex Based Plaster
to minimise the chance of the Solid Plaster cracking. (See your Solid Plasterer for correct materials and applications).
Visit the Warmington Web Site for "Hebel" instruction (PDF Download).. www.warmington.co.nz
4
Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.
Tested to current gas standards
SG-EG 700
SG-EG 780
2.75 kPa
2.75 kPa
2 X 1.1mm
2 X 1.2mm
2.5
2.5
0.75
0.75
29
38
Effect
Effect
3/8"
3/8"
1.5 kPa
1.5 kPa
2 X 1.8mm
2 X 2mm
1
1
0.3
0.3
35
41
Effect
Effect
3/8"
1/2"
GL 923
GL 900
20/04/2010
26/02/10
1149420106
1149520106
Hearth & Plinth material must
be built with non combustible
material eg. 9.5mm Promina,
Superlux, Etapan.
All Dimension are in mm.............Copyright ©
* Inlet Pressure not to exceed 4.0KPa
SG-EG 900
SG-EG 1100
2.75 kPa
2.75 kPa
2 X 1.3mm
2 X 1.4mm
2.5
0.75
0.75
42
Effect
Effect
1/2"
1/2"
1.5 kPa
1.5 kPa
2 X 2.2mm
2 X 2.4mm
1
0.3
48
Effect
Effect
1/2"
1/2"
GL 834
GL 876
26/06/09
24/12/09
1149720106
1149820106
HEARTH & PLINTH CONSTRUCTION DETAILS
Note: Hearth and Plinth construction
Plinth to be offset above hearth by the hearth finish-
ing's ( e.g. Tiles / Granite / Solid Plaster / etc.)
Raised hearth's & plinth's with cantilevered hearth's
must be adequately supported to take the weight in
accordance with the NZ Building Code.
Hearth & Plinth
29 March 2021
SG-EG 1250
2.75 kPa
4 X 1.1mm
2.5
2.5
0.75
50
60
Effect
1/2"
1.5 kPa
4 X 1.8mm
1
0.85
0.3
0.2
60
63
Effect
1/2"
GL 973
30/04/11
1149720106