Download Print this page

Warmington Studio Oven Installation Instructions Manual

Wood burner
Hide thumbs Also See for Studio Oven:

Advertisement

Quick Links

Studio Oven—Clean Air 2016
Visit
www.warmington.co.nz
Fire, Flue System and Instructions to Comply with ASNZS 2918:2001
Keep these Instructions for further reference......Ensure that you have the correct and current Installation details for the Warmington Fire
The Warmington unit is to be Installed by a Certified Warmington Installer or an Approved NZHHA Installation Technician .
See www.homeheat.co.nz/members for a Certified NZHHA SFAIT Installer in your area .
CLEARANCES TO COMBUSTIBLE SURFACES UNLESS STATED
Read all the Instructions carefully before commencing the Installation. Failure to follow these Instructions may result in a Fire Hazard and void the warranty
Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.
Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.
1
Studio Oven - Wood Burner
Installation Instructions
for Spec's, DWG's and PDF uploads of Fires
Installation
IMPORTANT
All Dimension are in mm.............Copyright ©
21 February 2017

Advertisement

loading
Need help?

Need help?

Do you have a question about the Studio Oven and is the answer not in the manual?

Questions and answers

Summary of Contents for Warmington Studio Oven

  • Page 1 Spec’s, DWG’s and PDF uploads of Fires Fire, Flue System and Instructions to Comply with ASNZS 2918:2001 Keep these Instructions for further reference……Ensure that you have the correct and current Installation details for the Warmington Fire Installation The Warmington unit is to be Installed by a Certified Warmington Installer or an Approved NZHHA Installation Technician .
  • Page 2 TEST REPORT : JOHN YOLLAND & ASSOCIATES LTD TEST REPORT NO : 98/17 Date of installation: _____/_____/20_____ Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm………….Copyright ©...
  • Page 3: Floor Protector

    Serial Number Check accordance with ASNZS 2918 (minimum Loading Badge Flue Shield height is 1200mm) Packed By : Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm………….Copyright ©...
  • Page 4 CLEARANCES TO BENCH TOP FOR STUDIO OVEN Description Bench Top Clearance To Bench Top Side To Flue Centre (Side) Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm………….Copyright ©...
  • Page 5 Tested Fuel Load (Softwood) Fire Box Litres : Approx. STUDIO OVEN up to 2.9 kg 29 Liters Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm………….Copyright ©...
  • Page 6 Ensure that Water is in the Wetback before Operating the Fire . Damage will result if the Wetback is dry . Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm………….Copyright ©...
  • Page 7: Seismic Restraints

    , bolt or screw. Ensure that the Seismic Restraint complies with ASNZS 2918:2001— Ref 3.8 Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm………….Copyright ©...
  • Page 8 Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm………….Copyright ©...
  • Page 9 CLEANING THE STUDIO OVEN The Studio Oven should only be cleaned when it is not being Used . The exterior can be dusted with a firm brush. Do not use a cloth to clean, as this will drag on the paint finish leaving a lint on the surface.
  • Page 10: Chimney Sweeping

    Replace Caps back in Position & the Fire is ready to use . ash etc & place back in position & close door . Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm………….Copyright ©...
  • Page 11 It is the responsibility of the installer to ensure that the installation of the flue kit complies with AS/NZ 2918:2001, the appli- ance manufacture’s specifications for flues and that relevant Local Body requirements are adhered to. Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm………….Copyright ©...
  • Page 12 All external air vents & ceiling penetrations must be bird proofed with permanently fixed screens. All flashing to comply with E2. Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm………….Copyright ©...
  • Page 13 Ensure that both glass & door surfaces are clean and true . remove the glass and any shards. Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm………….Copyright ©...
  • Page 14 Fit the bottom glass retainer. DO NOT OVER TIGHTEN AS GLASS MAY CRACK/BREAK . Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm………….Copyright ©...
  • Page 15 Tighten up the Cap Screws on the Top & Bottom Door Front first . Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm………….Copyright ©...
  • Page 16 Nip up screws while holding door in place, then tighten fully with a 5mm Allen Key. Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm………….Copyright ©...
  • Page 17: General Information & Operation

    GENERAL INFORMATION & OPERATION 1. Double Skin The Southern Series & Studio Oven Firebox is a radiant/convection stove – it has an inner and outer skin whereby room air flows between the surfaces, thus becoming hot and efficiently heating the room.
  • Page 18 10. Testing and Clean Air Approval The Studio Oven has been tested and approved to ASNZS 2918: 2001 specifications for solid fuel burning heaters .Contact with your local TA (Territorial Authority) to check for local compliance.
  • Page 19 Set slowly with successive burns. Contact your local Warmington Retailer if you have any other questions. Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm………….Copyright ©...
  • Page 20 NOTE: For Operation Instruction download from the website www.warmington.co.nz Industries 1994 LTD PO Box 58652, Botany 2163, Auckland www.warmington.co.nz Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm………….Copyright ©...