Important Notes; Gas Specifications - Warmington Traditional Fire - Gas 1000 Installation Instructions Manual

Traditional brick built open gas fire & gas burner
Table of Contents

Advertisement

IMPORTANT NOTES:

GAS SPECIFICATIONS

NOTE : All Test Pressures are tested by a Independent Test Lab
Nominal Pressure kPa
Nominal Injector Size mm
Burner Pressure High kPa
Burner Pressure Low kPa
MJ/h
Flame Effect Output Only
Supply Pipe Size dia—min
Nominal Pressure kPa
Nominal Injector Size mm
Burner Pressure High kPa
Burner Pressure Low kPa
MJ/h
Flame Effect Output Only
Supply Pipe Size dia—min
Lab. Test No
Lab. Test Dates
ESS Declaration No:
HEARTH & PLINTH CONSTRUCTION DETAILS
Note: Hearth and Plinth Construction.
Plinth to be offset above Hearth by the Hearth finishing (e.g. tiles/
granite/solid plaster/etc.)
Raised hearths & plinths with canter levered hearths must be
adequately supported to take the weight in accordance with the
NZ building code.
This is a raised & cantilevered hearth.
See page 13 for further raised hearth
details.
*Note: If Solid Plastering the Heat Cell structure, it is recommended to use a Fibreglass Mesh with a Latex Based Plaster to
minimise the chance of the Plaster cracking. (See your Solid Plasterer for correct materials and applications).
5
Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.
Tested to current gas standards
MODEL
TF 1000
LPG
2.75 kPa
2 X 1.1mm
Effect
Natural Gas
1.5 kPa
2 X 1.8mm
Effect
GL 923
20/04/2010
1149420106
All Dimension are in mm.............Copyright ©
* Inlet Pressure not to exceed 4.0kPa
TF 1200
2.75 kPa
2 X 1.2mm
2.5
2.5
0.75
0.75
29
38
Effect
3/8"
3/8"
1.5 kPa
2 X 2mm
1
1
0.3
0.3
35
45
Effect
3/8"
1/2"
GL 900
26/02/10
1149520106
Offset for
Hearth
finishing
23 November 2016
TF 1500
2.75 kPa
2 X 1.4mm
2.5
0.75
50
Effect
1/2"
1.5 kPa
2 X 2.4mm
1.0
0.3
58
Effect
1/2"
GL 876
24/12/09
1149820106
Hearth & Plinth material must
be built from non– combus-
tible material
eg. 9.5mm Promina,
Superlux, Etapan.
Offset