Warmington SG 700 Installation Manual

Sg gas burner into a warmington si wood open fire

Advertisement

14 June 2016
SG 700-780-900-1100 Burner Only
SG Gas Burner into a Warmington SI Wood Open Fire
Installation Guide Only
Warmington
SI Open
Wood Firebox.
Traditional Grate
& Burner
Warmington SG
Gas Burner.
Pure Grate
Classic
& Burner
Grate
Related documents
Fire and flue system installation, and instructions to comply with NZS 5601.1:2013,
3645.1(Int):2010, 3645.2(Int):2010, 5266:2014, 2918:2001.
The fireplace is constructed and tested to comply with NZS 4558(int):2013 "Decorative gas log and other fuel effect appliances".
Keep these instructions for further reference. Ensure that you have the correct and current installation details for the Warmington fireplace.
Installation
The Warmington unit is to be installed by a certified Warmington installer or an approved NZHHA installation technician.
See www.homeheat.co.nz/members for a certified NZHHA SFAIT Installer in your area.
A licenced certified gas fitter and licenced electrician are required to run power and gas supplies as required to the unit and any commissioning as part of the
installation process.The heater must be installed according to these instructions and in compliance with all relevant building, gas fitting, electrical and other
statutory regulations.
IMPORTANT
Read all the instructions carefully before commencing the Installation. Failure to follow these instructions may result in a fire hazard and void the warranty
Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.
1
All Dimension are in mm

Advertisement

Table of Contents
loading

Summary of Contents for Warmington SG 700

  • Page 1 The fireplace is constructed and tested to comply with NZS 4558(int):2013 “Decorative gas log and other fuel effect appliances”. Keep these instructions for further reference. Ensure that you have the correct and current installation details for the Warmington fireplace. Installation The Warmington unit is to be installed by a certified Warmington installer or an approved NZHHA installation technician.
  • Page 2 This will ensure that the draft in the flue system is always to the outside. “CAITEC AIR” the limits and requirements. See details in these Specs, on www.warmington.co.nz or contact your local Agent. Wind Noise: You may encounter wind noise in some installations.
  • Page 3 Burner Height Burner Depth Flue Diameter Min Flue CSA mm 31 416 31 416 49 087 49 087 Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm...
  • Page 4: Important Notes

    HEARTH CLEARANCES Note: For Combustible Floors Minimum Hearth of 300mm (A) must be maintained at any given height. Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm...
  • Page 5 The appliance and flue system must be tested in accordance with the relevant and current standards and the appropriate building codes. FLUED GAS APPLIANCES All Gas Fires requiring Warmington Flue Systems shall be Installed to the requirements of the current standards and shall be appropriately designed and constructed to permit safe and effective use.
  • Page 6: Bottom Row

    Number of Coals per Row Number of Rows Model Bottom Bottom Total SG 700 SG 780 SG 900 SG 1100 Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm...
  • Page 7: To Shut Down

    Turn control switch to 'PILOT'. Flame bed will extinguish. Pilot light may be left running or extinguished by switching to 'OFF' before closing cover. Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm...
  • Page 8 Replace the Base screw and check for leaks. 3 Flame Pilot in Assembled State Correct Operation of 3 Flame Pilot Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm...
  • Page 9 14 June 2016 POINTS OF SAFTEY—To the Customer /Home-Owner Your Warmington Gas Decorative Fire operates on the principle of dual radiant and convected heat. Therefore it is important to observe the following precautions associated with any heating appliance or open fire.
  • Page 10 WARNING: To ensure the Correct Operation of the Modulator it is necessary that the Plastic Cap is returned to its original location. Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm...
  • Page 11 NOTE: Keep a copy of these instructions for operating and maintenance guidelines. Industries 1994 LTD PO Box 58652, Botany 2163, Auckland www.warmington.co.nz Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm...