Gas Specifications - Warmington TFG 800 Installation And Operating Instructions Manual

Traditional brick built open gas fire & gas burner
Table of Contents

Advertisement

STAGE 3: GAS BURNER INSTALLATION AND TESTING FOR GASFITTER

3.1 GAS SPECIFICATIONS

Tested to current gas standards: AS/NZS 5601:2010, NZS 5266:2014, NZS/AS 4558:2013, NZS/AS 3645
NOTE : All test pressures are tested by an independent test lab
Inlet pressure not to exceed 4.0 kPa
MODEL
Nominal Pressure kPa
Nominal Injector Size mm
Burner Pressure High kPa
Burner Pressure Low kPa
MJ/h
Flame Effect Output Only
Supply Pipe Size dia—min
Natural Gas
Nominal Pressure kPa
Nominal Injector Size mm
Burner Pressure High kPa
Burner Pressure Low kPa
MJ/h
Flame Effect Output Only
Supply Pipe Size (minimum diameter)
Lab. Test No
Lab. Test Dates
ESS Declaration No
3.2 POSITIONING THE BURNER
The burner should be positioned in the centre of the firebox. Care should be taken to ensure the burner is placed in line with the Caitec
vents. The burner sits by self weight on the bricks and does not need to be bolted to the bricks.
There is a removable artificial steel brick at the back of the firebox, with two holes for gas feed and electronics feed where applicable.
3.3 VERMICULITE APPLICATION
Coarse vermiculite must be used so as not to block the gas outlet holes
Apply a thin layer of vermiculite over the burner, just enough to cover the burner tray.
Note: If the burner flame is uneven, the vermiculite may need to be changed or sifted to
remove the smaller pieces that can block the burners holes. The smaller pieces can
cause uneven burn and the unit to run dirty.
Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.
13
LPG
TFG 800
2.75 kPa
2x 1.0 mm
2.50
0.75
26
Effect
3/8"
1.5kPa
2x1.6 mm
1
0.3
27
Effect
3/8"
WAR 0112
01/06/2017
N/A
All dimensions are in mm
Copyright
5 September 2019
TFG 1000
TFG 1200
2.75 kPa
2 X 1.1mm
2 X 1.6mm
2.5
0.75
29
Effect
3/8"
1.5 kPa
2 X 1.8mm
2x 2.4mm
1
0.3
35
Effect
3/8"
GL 923
WAR 0115/0121
20/04/2010
7/10/2017
1149420106
2.75 kPa
2.5
0.75
65
Effect
1/2"
1.5 kPa
1
0.3
61
Effect
1/2"
N/A

Advertisement