This symbol denotes actions that the user must carry out. RESULTS OF ACTION This symbol denotes relevant results of actions. Other documents Besides this document the following material can be found on the Internet at www.turck.com: Data sheet EU Declaration of Conformity (current version) Feedback about these instructions We make every effort to ensure that these instructions are as informative and as clear as pos- sible.
CAD files in numerous export formats. The contact details of Turck subsidiaries worldwide can be found on p. [} 43]. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
The product is designed according to state-of-the-art technology. However, residual risks still exist. Observe the following warnings and safety notices to prevent damage to persons and property. Turck accepts no liability for damage caused by failure to observe these warning and safety notices.
M12 × 1 M12 × 1 Fig. 5: RU600U-M30E-2UP8X2T-H1151 Fig. 6: RUxxU-M18E-2UPN8X2T-H1151 M12 × 1 M12 × 1 Fig. 7: RUxxU-M30E-2UPN8X2T-H1151 Fig. 8: RU600U-M30M-2UP8X2-H1151 4.1.1 Indication elements The ultrasonic sensors have a green and a yellow LED which are visible via four indication points. Only one LED can be active at one time. If an LED is active, all four indication points are lit.
Cloth, sand or grains absorb some of the sonic energy. Foams and skins are particularly poor reflectors. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Functions and operating modes The ultrasonic sensors are provided with two switching outputs that can be set independently of each other. The sensors can be operated as diffuse mode or retroreflective sensors during normal operation. The user can set an individual switch point as well as a window or hysteresis function.
Page 12
Fig. 11: Window function – Behavior of the switching output Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Hysteresis function When using the hysteresis function, a switch window is taught in that is defined by two switch- ing points. The switching outputs have the following behavior as outputs: If an object is moved away from the sensor, the switching output is switched on for as long as the object is located between the beginning of the detection range and switching point 2.
MW-18 6945004 Mounting bracket, stainless steel, 19,7 for M18 15,9 19,1 50,8 25,4 14,3 44,5 34,8 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Page 15
20,6 57,2 44,5 10,3 In addition to the above connection cables, Turck also offers other cable types for specific applications with the correct terminals for the device. More information on this is available from the Turck product database at www.turck.de/products in the Connectivity area.
Connection Connect the female connector of the connection cable to the male connector of the sensor. Connect the open end of the connection cable to the power supply and/or processing units. Connection diagram (BN) 2 WH (BU) (WH) –...
Commissioning Commissioning The device is operational automatically once the cables are connected and the power supply is switched on. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Operation NOTICE Incorrect use of the sensor Possible damage to property due to malfunction Prevent the accumulation of material deposits on the surface of the sonic trans- ducer. Keep the blind zone of the sensor clear. Refer to the technical data for the blind zone S of the sensor.
Aborting the teach-in operation: Teach-in U for at least 2 s. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Setting via teach adapter Selecting the output Select switching output 1: Press and hold down the pushbutton on the adapter to GND for 2…7 s. Select output 2: Press and hold down the pushbutton on the adapter to GND for 8…13 s. Setting the switching point Switching point Out1...
Page 22
The switching points have been successfully taught in if the green LED flashes for 1.5 s at a frequency of 5 Hz. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Page 23
Window function – switching between hysteresis and window Choice: * Set window window / function before hysteresis* Out1 Out2 GND/T1 > 2 s 7 s GND/T1 > 8 s 13 s LED GN 1 × 1 Hz LED GN 2 × 1 Hz Measure and save GND/T1 >...
Page 24
The output function has been successfully inverted as an NC contact if the green LED flashes for 1.5 s at a frequency of 5 Hz. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Page 25
Setting operation as a retroreflective sensor Retroreflective sensor Position sensor UB/T2 > 20 s LED YE 1 × 1 Hz Fail LED GN/YE LED GN 1.5 s × 5 Hz 1.5 s × 5 Hz Normal operation Fig. 25: Setting operation as a retroreflective sensor ...
Page 26
The device has been successfully reset to the factory settings if the green LED flashes for 1.5 s at a frequency of 5 Hz. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Setting by manual bridging (shorting) Selecting the output Select switching output 1: Bridge pin 3 (BU) with pin 5 (GY) for 2…7 s. Select output 2: Bridge pin 3 (BU) with pin 5 (GY) for 8…13 s. Setting the switching point Switching point Out1 Out2...
Page 28
The switching points have been successfully taught in if the green LED flashes for 1.5 s at a frequency of 5 Hz. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Page 29
Window function – switching between hysteresis and window Choice: * Set window window / function before hysteresis* Out1 Out2 GND/T1 > 2 s 7 s GND/T1 > 8 s 13 s LED GN 1 × 1 Hz LED GN 2 × 1 Hz Measure and save GND/T1 >...
Page 30
The output function has been successfully inverted as an NC contact if the green LED flashes for 1.5 s at a frequency of 5 Hz. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Page 31
Setting operation as a retroreflective sensor Retroreflective sensor Position sensor UB/T2 > 20 s LED YE 1 × 1 Hz Fail LED GN/YE LED GN 1.5 s × 5 Hz 1.5 s × 5 Hz Normal operation Fig. 31: Setting operation as a retroreflective sensor ...
Page 32
The device has been successfully reset to the factory settings if the green LED flashes for 1.5 s at a frequency of 5 Hz. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Setting via the pushbuttons NOTE The devices with a teach button are ready for teaching in up to 300 s after the power supply is switched on. The teach button is then automatically locked. A new teach-in operation is only possible after the power supply has been reset. Selecting the output ...
Page 34
The switching points have been successfully taught if the green LED flashes for 1.5 s at a frequency of 5 Hz. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Page 35
Window function – switching between hysteresis and window Choice: * Set window window / function before hysteresis* Out1 Out2 GND/T1 > 2 s 7 s GND/T1 > 8 s 13 s LED GN 1 × 1 Hz LED GN 2 × 1 Hz Measure and save GND/T1 >...
Page 36
The output function has been successfully inverted as an NC contact if the yellow LED flashes for 1.5 s at a frequency of 5 Hz. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Page 37
Setting operation as a retroreflective sensor Retroreflective sensor Position sensor UB/T2 > 20 s LED YE 1 × 1 Hz Fail LED GN/YE LED GN 1.5 s × 5 Hz 1.5 s × 5 Hz Normal operation Fig. 37: Setting operation as a retroreflective sensor ...
Page 38
The device has been successfully reset to the factory settings if the green LED flashes for 1.5 s at a frequency of 5 Hz. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Troubleshooting If the device does not function as expected, first check whether ambient interference is present. If there is no ambient interference present, check the connections of the device for faults. If there are no faults, there is a device malfunction. In this case, decommission the device and replace it with a new device of the same type.
Disposal The devices must be disposed of correctly and must not be included in general household garbage. Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Technical Data Technical data RU40…- RU130…- RU40…- RU130…- RU300…- RU600…- M18… M18… M30… M30… M30… M30… Blind zone S 2.5 cm 15 cm 2.5 cm 15 cm 30 cm 60 cm Operating range 40 cm 130 cm 40 cm 130 cm 300 cm 600 cm Opening angle...
Switching output 2 Switching point output 2 130 cm 300 cm 600 cm (end of detection range) (end of detection range) (end of detection range) Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Turck Subsidiaries - Contact Information Germany Hans Turck GmbH & Co. KG Witzlebenstraße 7, 45472 Mülheim an der Ruhr www.turck.de Turck Australia Pty Ltd Australia Building 4, 19-25 Duerdin Street, Notting Hill, 3168 Victoria www.turck.com.au Belgium TURCK MULTIPROX Lion d'Orweg 12, B-9300 Aalst www.multiprox.be...
Page 44
Árpád fejedelem útja 26-28., Óbuda Gate, 2. em., H-1023 Budapest www.turck.hu Turck Inc. 3000 Campus Drive, USA-MN 55441 Minneapolis www.turck.us Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com...
Page 45
Over 30 subsidiaries and over 60 representations worldwide! 100031796 | 2021/06 100031796 www.turck.com...
Need help?
Do you have a question about the RU40-M18 Series and is the answer not in the manual?
Questions and answers