  • ENGLISH, page 29
A - CONNEXIONS
IT IS COMPULSORY TO SET THE DIP
13 OF THE CONTROL PANEL IN THE ON
POSITION.
T1
T2
JC
JC
JB
JA
POWER 400 Vac + N
J1
L1 - N
230 Vac 50/60Hz power supply (120Vac 60Hz upon request)
J2
Flashing light (max 40W )
U
Motor common connection
V-W
Motor phases and capacitor connections
J3
R-AUX
Auxiliary relay contact (NO) Max 700 W
SIGNAL
Gate open state (24 Vdc 3 W max)
COM A+
Common contacts / Positive 24 Vdc
J4
A+ COM
+ 24Vdc accessories power supply / Common contacts
A-
- 24Vdc accessories power supply
A+ TEST
+ 24Vdc photocells self-test power supply
J5
COM A+
Common contacts / Positive 24 Vdc
B.I.O.
Contact (NO) dedicated to a clock
PED.
Pedestrian opening contact (NO)
START
Single pulse contact (NO)
CLOSE
Closing impulse contact (NO)
OPEN
Opening impulse contact (NO)
J6
COM A+
Common contacts / Positive 24 Vdc
STOP
STOP impulse contact (NC)
PHOT 1
Photocells contact 1 (NC)
PHOT 2
Photocells contact 2 (NC)
EDGE 1
Edge 1 contact (NC)
EDGE 2
Edge 2 contact (NC)
J7
COM A+
Common contacts / Positive 24 Vdc
LIMIT SWITCH
Limit switches that cuts OFF the motor
J8
J7
J6
J5
J4
J3
J2
J1
F1
MOTOR
J8
J9
J10
J11
J12
J13
J14
J15
J16
J17
F1
CARD R2
33
PROBE
IS NOT AVAILABLE
ENCODER
IS NOT AVAILABLE
RS485 termination of J11
APP+
Connector for APP+ card
APP
Connector for APP card
SERIAL COM /
Connector for serial connection
SYNC
-
-
RADIO
Connector for radio module ACG8069
RADIO
Connector for radio receiver RIB, 24 Vdc supply
433 MHz Radio antenna
PROG.
Programming button
Trimmer for automatic closing time adjustment (DISABLED
TCA
DEFAULT AND DL11 LED OFF)
LOW SP
IS NOT AVAILABLE
TORQUE
IS NOT AVAILABLE
T5A
Fuse for motor protection
T1 - T2 T
POWER RELAYS FOR THE COMMAND OF THE MOTOR
R-N
SINGLE PHASE POWER SUPPLY - NEUTRAL
JA
CONTACTS FOR THE EARTH CONECTION
U-V-W
MOTOR CONNECTION
SINGLE PHASE POWER SUPPLY FOR THE L1 CONTROL PANEL TO BE
JB
L1-N
DONE BY THE MANUFACTURER
CONNECTION TO THE POWER RELAYS, TO BE DONE BY
JC
X-Y-Z
THE MANUFACTURER
G
B
PROG
J11
J12
J13
J14
J15
J16
J17