3.3 Function description

Illustration
C
21
12 | 60
Description / explanation
The condensate flows via the condensate inlet [C] into the
BEKOMAT
level in the housing [21] is permanently monitored by a
capacitive sensor in the sensor tube [46].
46
30
25
The control actuates the pilot valve with valve core [30]
and the membrane [25] opens the condensate
B
discharge [B] to the condensate drain system.
Once the BEKOMAT
discharge [B] is closed tightly again before any loss of
compressed gas can occur.
Original installation and operation manual
and collects in the housing [21]. The filling
®
has been emptied, the condensate
®