Recommended Guidelines - jbc PHSE-K Instruction Manual

Small preheater set
Table of Contents

Advertisement

Setting Thermocouples Function
Select Thermocouples from the Work mode menu to set them up.
The thermocouples (TC) can work in three diferent ways depending on what is needed.
C
· Control: the unit mantains the selected temperature.
P
· Protection: the Heater Unit stops if the TC reaches the selected temperature.
· Info: the TC temperature is shown in the work screen.
The TC1 is always working in Control mode for the Temperature mode as well as for Profiles mode.
The temperature of each TC can also be selected from the work screen.

Recommended Guidelines

1. Place the Control Thermocouple as near as possible to the component being worked on.
2. If there are any sensitive components, use a Thermocouple as protection.
You can select the protection temperature in the Thermocouples menu. If the selected temperature
is reached, the Heater Unit will stop the process and a warning message will be shown.
Control
Thermocouple
3. IPC* does not recommend exceeding ramp-up rates over 3 - 4 °C / sec (5 - 7 °F / sec) so as to
reduce the risk of thermal stress on the PCB.
* IPC was founded in the U.S. in 1957 as the Institute for Printed Circuits and is committed to becoming the
most recognized international industry association for the electronics manufacturing industry.
Thermocouples
Fix with Kapton Tape
w w w.jbctools.com
Protection
Thermocouple
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Phse-1kaPhse-2kaPhse-9ka

Table of Contents