Profile Editor - jbc PHSE-K Instruction Manual

Small preheater set
Table of Contents

Advertisement

Profile Editor

Profi le Editor
Profile Name
Data for
these Points
JBC Set Profiles
There are 3 profiles predefined by JBC: A, B and C. The difference between them is the number of
steps: 2, 3 or 4. The thicker your PCB is and the more layers it contains, the more steps are needed
to obtain a gradual warming.
These profiles are not modifiable but can be used as a template to create your own profiles.
120
C
º
14:15
5m 00s
20
C
º
180
240
300
Time
2m 00s
PCB Reference
Specifications:
Profiles set using the low position of the PHXL-SA Support (28 mm in height between the PCB and the heating area).
10
The Profile editor can be opened from the main menu or from the Profiles mode work
screen by pressing the 'OK' button.
In this mode you can edit as many as 25 profiles of temperature.
PROFILE1
200
100
0
Point
2/3
JBC-A
2 steps
120
C
º
80
C
º
20
C
º
5'
8'
3'30"
FR4 1,6mm thick
and 2 layers.
14:15
5m 00s
60
120
180
Temp
Time
120
C
º
2m 00s
JBC-B
3 steps
120
C
º
100
C
º
80
C
º
20
C
º
5'30"
8'
FR4 1,6mm thick
and 6 layers.
240
300
JBC-C
4 steps
5'
5'
8'
FR4 2,2mm thick
and 6 layers.
120
C
º
Menu
Options
· Add Point
· Delete Point
· Load Profile
· Save Profile
20
C
º
· Exit
150
100
25
8'

Advertisement

Table of Contents
loading

This manual is also suitable for:

Phse-1kaPhse-2kaPhse-9ka

Table of Contents