ETH-SP-G2, one near the device and the other at the entry point to the building. The ETH-SP-G2 will absorb power surges and safely discharge them into the ground. Note: For guidelines about grounding and lightning protection, follow your local electrical regulatory codes. GBE-LR ES-8-150W ≤ ETH-SP-G2 ETH-SP-G2...
Hardware Overview LEDs 60 GHz Lights steady blue when 60 GHz link is ready. 5 GHz Lights steady blue when the 5 GHz link is ready. The LED will light steady blue when an active Ethernet connection is made to the Ethernet port and flash when there is activity. Power/Status...
Page 5
Color Status Flashing White Bootup in progress. Ready for use, not connected to Ubiquiti® White Network Management System (UNMS ). See ™ “UNMS Management”. Blue Ready for use, connected to UNMS. Steady Blue with Ready for use, unable to connect to UNMS, Occasional Flashing check connection to UNMS server.
Page 6
Ports PoE IN Port This Gigabit Ethernet port is used to connect the power and should be connected to the LAN and DHCP server. Default IP address: 192.168.1.20. Reset Button To reset to factory defaults, press and hold the Reset button for more than 10 seconds while the device is powered on.
Page 8
3. OPTIONAL: Attach the stabilizer arms for added support.
Page 9
Note: The GBE-LR can mount on either side of the pole. This section shows the GBE-LR mounted on the left; the procedure for mounting on the right is similar. Left Right...
Page 10
Note: Rotate the Mounting Bracket clockwise until it locks into position.
Connecting Power WARNING: The switch port must comply with the power specifications listed in “Specifications”. (Optional)
Page 16
Configuration The device is set to DHCP by default, so it will try to automatically obtain an IP address. If that fails, it will use the default fallback IP address, 192.168.1.20. Proceed to the appropriate section, DHCP or “Fallback IP Address”: DHCP Use one of the following methods: •...
Page 17
4. Enter a Username and Password, confirm the Password, and click Save. 5. Click the icon. 6. Configure the following settings: a. For one device, enable Access Point mode. For the other device (the Station), keep Access Point disabled. b. Enter a name in the SSID field. This must be the same on both the AP and the Station.
Page 18
8. Configure each device (AP and Station) with a unique IP address: a. Click the icon. b. Review the Network settings to ensure that each device has a unique IP address. Each can get its IP address via DHCP, or use a static IP address. •...
Page 19
Fallback IP Address 1. Ensure that your computer (or other host machine) is connected to the same LAN as the GigaBeam. 2. Configure the Ethernet adapter on your host system with a static IP address on the 192.168.1.x subnet. 3. Launch your web browser. Type https://192.168.1.20 in the address field, and press enter (PC) or return (Mac).
Page 20
6. Click the icon. 7. Configure the following settings: a. For one device, enable Access Point mode. For the other device (the Station), keep Access Point disabled. b. Enter a name in the SSID field. This must be the same on both the AP and the Station.
Page 21
9. Configure each device (AP and Station) with a unique IP address: a. Click the icon. b. Review the Network settings to ensure that each device has a unique IP address. Each can get its IP address via DHCP, or use a static IP address. DHCP •...
Page 22
Alignment Tips • To accurately align the radios for best performance, you MUST align only one end of the link at a time. • You may need to use additional hardware to compensate for issues such as the improper orientation of a mounting pole or significant elevation differences between radios.
Page 23
Adjust the elevation: Note: Do NOT make simultaneous adjustments on the AP and Station. Station Visually aim the Station at the AP. To adjust the Station’s position, adjust the azimuth and elevation as described in step 1. 3. Open the Configuration Interface. Select Tools and then select Align Antenna.
Installer Compliance Responsibility Devices must be professionally installed and it is the professional installer’s responsibility to make sure the device is operated within local country regulatory requirements. Antenna The 5GHz Output Power field is provided to the professional installer to assist in meeting regulatory requirements.
Safety Notices Read, follow, and keep these instructions. Heed all warnings. Only use attachments/accessories specified by the manufacturer. WARNING: Do not use this product in a location that can be submerged by water. WARNING: Avoid using this product during an electrical storm.
Page 28
Compliance FCC / CAN ICES-3(A)/NMB-3(A) Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules and ISED Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions.
IMPORTANT NOTE: Radiation Exposure Statement: • This equipment complies with radiation exposure limits set forth for an uncontrolled environment. • This equipment should be installed and operated with minimum distance 110 cm between the radiator and your body. • This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Page 30
CE Marking CE marking on this product represents the product is in compliance with all directives that are applicable to it. Country List AT BE BG CY CZ DE DK EE EL ES FI FR HR IE IT LV LT LU MT NL PL PT RO BFWA (Broadband Fixed Wireless Access) members noted in blue...
Page 31
Deutsch Die Europäische Richtlinie 2012/19/EU verlangt, dass technische Ausrüstung, die direkt am Gerät und/oder an der Verpackung mit diesem Symbol versehen ist, nicht zusammen mit unsortiertem Gemeindeabfall entsorgt werden darf. Das Symbol weist darauf hin, dass das Produkt von regulärem Haushaltmüll getrennt entsorgt werden sollte. Es liegt in Ihrer Verantwortung, dieses Gerät und andere elektrische und elektronische Geräte über die dafür zuständigen und von der Regierung oder örtlichen Behörden dazu bestimmten Sammelstellen zu...
English Hereby, UBIQUITI, declares that this GBE-LR device, is in compliance with the essential requirements and other relevant provisions of Directives 2014/53/EU, 2014/30/EU, 2014/35/EU. The full text of the EU declaration of conformity is available at the following internet address: ui.com/compliance...
Page 33
Az EU-megfelelőségi nyilatkozat teljes szövege elérhető a következő internetes címen: ui.com/compliance Íslenska [Icelandic] Hér, UBIQUITI, því yfir að þetta GBE-LR tæki er í samræmi við grunnkröfur og önnur viðeigandi ákvæði tilskipana 2014/53/ESB, 2014/30/ESB, 2014/35/ESB. Fullur texti ESB samræmisyfirlýsing er að finna á eftirfarandi netfangi: ui.com/compliance Italiano [Italian] Con la presente, UBIQUITI, dichiara che questo dispositivo GBE-LR, è...